APAR status
Closed as fixed if next.
Error description
A FM model is using a Parameter Map to set the data source connection. When a report with a repeater table containing a crosstab is executed, not only the datasource connection returned by the Parameter Map is used, but also the default value of the parameter map is tested. As each of the data source connection has different signons, the report fails with the error QE-DEF-0283 THE CONNECTION IS AMBIGUOUS.
Local fix
As default value of the parameter map, use a datasource that does not have multiple connections or signons.
Problem summary
**************************************************************** * USERS AFFECTED: * * All Users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to IBM Cognos Analytics 11.1.5 * ****************************************************************
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH13865
Reported component name
COG REPORT STUD
Reported component ID
5724W12RS
Reported release
B0A
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-06-26
Closed date
2019-12-23
Last modified date
2019-12-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHNWW","label":"Report Authoring v11x"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B0A","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
23 December 2019