Error description

  • The following changes are included in this APAR:
    1. The High Availability Utility (HALOAD) loading to a target
    accelerator at mainenance level  IDAA 7.1 PTF-7
    (IDAA APAR PH10050), the Accelerator Loader is modified to
    directly interface with ACCEL_LOAD_TABLES. For HALOAD on
    IDAA 7.1 PTF-7, the Accelerator Loader LOADLIB is not required
    in the DSNUTILU Work Load Manager (WLM) address space, instead
    Accelerator Loader LOADLIB has to be included into the WLM
    environment that runs the SYSPROC.ACCEL_LOAD_TABLES stored
    procedure.  Any target accelerator that is prior to IDAA V7.1
    PTF-7 still requires the Accelerator Loader load library to be
    available in the DSNUTILU address space.
    2. On a new install of Accelerator Loader, TCz jobs new install
    DDL modified to tolerate Db2 V12 Function Level 504. With this
    enhancement, for a new installation of Accelerator Loader where
    product repository table spaces do not exist, the repository
    table spaces are now created as partition-by-growth universal
    table spaces (UTS). To implement this change, TCz template
    HLODDL, which is used to generate the DDL to create the
    repository objects, was modified. The MAXPARTITIONS parameter
    is now specified when creating the repository table spaces.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: The following changes are included in   *
    *                      this APAR:                              *
    *                                                              *
    *                      1. The High Availability Utility        *
    *                         (HALOAD) loading to a target         *
    *                         accelerator at maintenance level     *
    *                         IDAA 7.1 PTF-7 (IDAA APAR PH10050),  *
    *                         the Accelerator Loader is modified   *
    *                         to directly interface with           *
    *                         ACCEL_LOAD_TABLES. For HALOAD on     *
    *                         IDAA 7.1 PTF-7, the Accelerator      *
    *                         Loader LOADLIB is not required in    *
    *                         the DSNUTILU Work Load Manager       *
    *                         (WLM) address space, instead         *
    *                         Accelerator Loader LOADLIB has to    *
    *                         be included into the WLM environment *
    *                         that runs the                        *
    *                         SYSPROC.ACCEL_LOAD_TABLES stored     *
    *                         procedure. Any target accelerator    *
    *                         that is prior to IDAA V7.1 PTF-7     *
    *                         still requires the Accelerator       *
    *                         Loader load library to be available  *
    *                         in the DSNUTILU address space.       *
    *                      2. On a new install of Accelerator      *
    *                         Loader, TCz jobs new install DDL     *
    *                         modified to tolerate Db2 V12         *
    *                         Function Level 504                   *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    The following changes are included in this APAR:
    
    1. The High Availability Utility (HALOAD) loading to a target
       accelerator at maintenance level IDAA 7.1 PTF-7 (IDAA APAR
       PH10050), the Accelerator Loader is modified to directly
       interface with ACCEL_LOAD_TABLES. For HALOAD on IDAA 7.1
       PTF-7, the Accelerator Loader LOADLIB is not required in the
       DSNUTILU Work Load Manager (WLM) address space, instead
       Accelerator Loader LOADLIB has to be included into the WLM
       environment that runs the SYSPROC.ACCEL_LOAD_TABLES stored
       procedure. Any target accelerator that is prior to IDAA V7.1
       PTF-7 still requires the Accelerator Loader load library to
       be available in the DSNUTILU address space.
    2. On a new install of Accelerator Loader, TCz jobs new install
       DDL modified to tolerate Db2 V12 Function Level 504
    

Problem conclusion

  • Apply the PTF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH13717

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-06-21

  • Closed date

    2019-09-04

  • Last modified date

    2019-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI65065

Modules/Macros

  • HLO#A001 HLO#ACIR HLO#ACIW HLO#ACON HLO#ACRD HLO#ACUP HLO#ADIS
    HLO#ADSC HLO#AEXT HLO#AFMT HLO#AFRR HLO#ALLO HLO#AMIN HLO#AOBP
    HLO#ASYS HLO#AUMX HLO#AUTO HLO#BCLR HLO#BCTC HLO#BIND HLO#BPRI
    HLO#BRS  HLO#BSQL HLO#BTMP HLO#BULD HLO#CARD HLO#CHKR HLO#CL
    HLO#CL64 HLO#CL7  HLO#CL8  HLO#CLLS HLO#CMTS HLO#CMTU HLO#CNTL
    HLO#CONT HLO#CPM  HLO#CPNT HLO#CPOL HLO#DB2V HLO#DCMD HLO#DISP
    HLO#DSAF HLO#DSPL HLO#DYNL HLO#ECIC HLO#EMCS HLO#EMIC HLO#EMID
    HLO#ENQS HLO#ENVF HLO#EPRI HLO#FCPY HLO#ICAI HLO#ICAL HLO#ICCC
    HLO#ICCI HLO#ICP7 HLO#ICP8 HLO#ICPO HLO#IDCF HLO#IDSA HLO#IERR
    HLO#IHSA HLO#IKPL HLO#IKPN HLO#ILGP HLO#ILRA HLO#ILRS HLO#ILSA
    HLO#INIT HLO#IOPF HLO#IPIE HLO#IPPB HLO#IPPC HLO#IPPD HLO#IPPH
    HLO#IPPL HLO#IPPN HLO#IPPS HLO#IRPL HLO#ISNA HLO#IX   HLO#IX10
    HLO#IX7  HLO#IX8  HLO#IX9  HLO#IXN8 HLO#IXP7 HLO#IXP8 HLO#IXP9
    HLO#IXPT HLO#JPRI HLO#LGAA HLO#LGAC HLO#LGAF HLO#LGAI HLO#LGAP
    HLO#LOGR HLO#LPIO HLO#LRD6 HLO#LRDR HLO#LRPT HLO#MAIN HLO#MDRV
    HLO#MEPL HLO#MLOG HLO#MMGR HLO#MPRI HLO#MREP HLO#MTIO HLO#OBEX
    HLO#OBRP HLO#OPCL HLO#OPRI HLO#OPVD HLO#OS   HLO#OUT2 HLO#PDEP
    HLO#PITS HLO#PLOG HLO#PRNG HLO#PRSE HLO#QSAM HLO#RANG HLO#RCFS
    HLO#RESM HLO#RH   HLO#RH10 HLO#RM24 HLO#RPRP HLO#RUNT HLO#SCHD
    HLO#SCPY HLO#SETP HLO#SETR HLO#SQLE HLO#STAT HLO#SUBD HLO#SUBX
    HLO#SYSC HLO#TABL HLO#TB   HLO#TB7  HLO#TB8  HLO#TBPT HLO#TP
    HLO#TP10 HLO#TS   HLO#TS10 HLO#TS7  HLO#TS8  HLO#TS9  HLO#TSS
    HLO#TSSA HLO#TUTL HLO#UPRI HLO#UTED HLO#UTLL HLO#UTLS HLO#UTOB
    HLO#UTOP HLO#VERT HLO#VSAM HLO#WRIT HLO#XMLC HLO#XMLD HLO#XMLI
    HLO#XMLS HLO#XMLU HLO$ACCS HLO$ACES HLO$ADM2 HLO$ADMN HLO$ADMS
    HLO$ALLC HLO$BCHJ HLO$BCPY HLO$BDSN HLO$BGDG HLO$BJBC HLO$BJBN
    HLO$BMSD HLO$BMSG HLO$BPRD HLO$BRST HLO$BULD HLO$BULJ HLO$BUT2
    HLO$BUTA HLO$BUTB HLO$BUTC HLO$BUTD HLO$BUTE HLO$BUTG HLO$BUTH
    HLO$BUTI HLO$BUTJ HLO$BUTK HLO$BUTM HLO$BUTP HLO$BUTQ HLO$BUTR
    HLO$BUTS HLO$BUTT HLO$BUTU HLO$BUTV HLO$BUTX HLO$BUTZ HLO$CALL
    HLO$CHAR HLO$CRID HLO$CTCM HLO$DCVT HLO$DLOG HLO$DSET HLO$EDIT
    HLO$EDT2 HLO$EDTI HLO$EDTT HLO$EQRY HLO$EXPB HLO$EXPD HLO$EXPF
    HLO$FCOL HLO$IMPD HLO$IMPE HLO$IMPF HLO$INFO HLO$JBRK HLO$JOBD
    HLO$JOBR HLO$JOPT HLO$JOTM HLO$JOVR HLO$JPRC HLO$JPRD HLO$JPRJ
    HLO$JPRU HLO$LJBO HLO$LOBJ HLO$LPRD HLO$LSTP HLO$OINC HLO$OPRC
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R210 PSY UI65065

       UP19/09/12 P F909

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0"}]

Document Information

Modified date:
30 March 2021