APAR status
Closed as program error.
Error description
Caused by: java.lang.NullPointerException at org.eclipse.emf.ecore.impl.EClassImpl.getEStructuralFeature(ECla ssImpl.java:803) at com.ibm.ws.bo.BOModelHolder.getElement(BOModelHolder.java:446) at com.ibm.ws.bo.service.BOTypeImpl.getTypeByElement(BOTypeImpl.jav a:103) at com.ibm.ws.bo.delegate.BOTypeDelegate.getTypeByElement(BOTypeDel egate.java:55) at com.ibm.ws.sibx.mediation.primitives.headersetter.HeaderTypeSOAP .getBOTypeByElementFromQName(HeaderTypeSOAP.java:2422) at com.ibm.ws.sibx.mediation.primitives.headersetter.HeaderTypeSOAP .findBOTypes(HeaderTypeSOAP.java:1621) at com.ibm.ws.sibx.mediation.primitives.headersetter.HeaderTypeSOAP .validateValues(HeaderTypeSOAP.java:1602) at com.ibm.ws.sibx.mediation.primitives.headersetter.HeaderElement. validate(HeaderElement.java:317)
Local fix
n.a
Problem summary
**************************************************************** * USERS AFFECTED: All users of IBM WebSphere Application * * Server and using BPM (Business Process * * Manager) * **************************************************************** * PROBLEM DESCRIPTION: NullPointerException occurs in EMF * * (Eclipse Modeling Framework) during * * initialization. * **************************************************************** * RECOMMENDATION: * **************************************************************** The following null pointer exception might be encountered when running BPM: Caused by: java.lang.NullPointerException at org.eclipse.emf.ecore.impl.EClassImpl.getEStructuralFeature(ECla ssImpl.java:803) at com.ibm.ws.bo.BOModelHolder.getElement(BOModelHolder.java:446) at com.ibm.ws.bo.service.BOTypeImpl.getTypeByElement(BOTypeImpl.jav a:103) at com.ibm.ws.bo.delegate.BOTypeDelegate.getTypeByElement(BOTypeDel egate.java:55) at com.ibm.ws.sibx.mediation.primitives.headersetter.HeaderTypeSOAP .getBOTypeByElementFromQName(HeaderTypeSOAP.java:2422) at com.ibm.ws.sibx.mediation.primitives.headersetter.HeaderTypeSOAP .findBOTypes(HeaderTypeSOAP.java:1621) at com.ibm.ws.sibx.mediation.primitives.headersetter.HeaderTypeSOAP .validateValues(HeaderTypeSOAP.java:1602) at com.ibm.ws.sibx.mediation.primitives.headersetter.HeaderElement. validate(HeaderElement.java:317) The EMF code is not thread-safe. The proper way to use EMF is to do all model initialization using a single thread. After initialization, multi-threaded access can be used. We suspect that BPM code is modifying the model after initialization is complete. This is difficult to prove since the problem could not be produced when debug code was active.
Problem conclusion
Double-check locking was added to EMF to provide a small measure of thread-safety. This protects the area of EMF code where this particular NullPointerException is thrown. The fix for this APAR is currently targeted for inclusion in fix pack 8.5.5.16 and 9.0.5.1. Please refer to the Recommended Updates page for delivery information: http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
Temporary fix
Comments
APAR Information
APAR number
PH12669
Reported component name
WEBS APP SERV N
Reported component ID
5724H8800
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-05-29
Closed date
2019-07-08
Last modified date
2019-07-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WEBS APP SERV N
Fixed component ID
5724H8800
Applicable component levels
R850 PSY
UP
R900 PSY
UP
Document Information
Modified date: