Error description
In order for a CICS region ( MAS ) to connect to a CICSPlex, there has to be a CSYSDEF definition for the MAS. That definition includes the name of the region, the APPLID, and the SYSID it is supposed to be using. If the MAS tries to connect using a different SYSID than the one in the CSYSDEF, CPSM issues the following message in the CMAS EYULOG: . EYUTS0023E Topology connect of CICS System sysname not initiated. CPSM Data Repository CSYSDEF and MAS SysIds do not match. APPLID(applid) CICSplex(plexname). . The SYSID of the CICS region is easy to determine, but it is often more of a challenge to find out what the CSYSDEF record contains. Sometimes a working WUI or CICS Explorer session can be used, or the CPSM XDBT utility can be used. . It would be better though for the difference in SYSIDs to be reported directly in the text of the EYUTS0023E message. . . Additional Symptom(s) Search Keyword(s): KIXREVGJT
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of CPSM. * **************************************************************** * PROBLEM DESCRIPTION: Improve serviceability information * * for message EYUTS0023E. * **************************************************************** Message EYUTS0023E is issued when there is a mismatch between the CSYSDEF of a MAS and the SYSIDNT system initialisation parameter that MAS uses when connecting to a CMAS. The message merely states that there is a mistmatch between these two values but does not detail what these values are. Keywords: msgEYUTS0023E EYUTS0023E
Problem conclusion
Temporary fix
Comments
CPSM message EYUTS0023E has been updated to include message inserts for the expected CSYSDEF SYSID and the actual CICS SYSIDNT system initialisation parameter. Module EYU0TIST has been modified to populate the message inserts in the updated message EYUTS0023E. The CICSPlex SM Messages and Codes Manual and the CICS Knowledge Center will update message text for message EYUTS0023E as: Topology connect of CICS System <sysname> not initiated. CPSM Data Repository CSYSDEF (SYSID=<definedsysid>) and MAS SysId (SYSID=<sysidnt>) do not match. APPLID(<applid>) CICSplex(<plexname>).
APAR Information
APAR number
PH12233
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
00M
Status
CLOSED UR3
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-05-17
Closed date
2019-08-07
Last modified date
2019-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI64630 UI64633 UI64635
Modules/Macros
EYU0TIST EYUMCTSC EYUMCTSE EYUMCTSK
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R00M PSY UI64630
UP19/08/08 P F908
R10M PSY UI64633
UP19/08/08 P F908
R20M PSY UI64635
UP19/08/08 P F908
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"","label":""}}]