IBM Support

PH11523: FIX TO NOT UPDATE THE REFRESH TIMESTAMP IF NO DATA IS LOADED INTO THE TABLE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The refresh timestamp is being updated even though no data has
    been loaded. The fix is to NOT update the refresh timestamp if
    no data is loaded into the table.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Enhancement to NOT update the refresh   *
    *                      timestamp if no data is loaded into the *
    *                      table                                   *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF                                *
    ****************************************************************
    Enhancement to NOT update the refresh timestamp if no data is
    loaded into the table
    

Problem conclusion

  • APPLY the PTF
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH11523

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-04-26

  • Closed date

    2019-10-16

  • Last modified date

    2019-11-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI65915 010PC2Ÿ 010PC2Ÿ

Modules/Macros

  • HLO#A001 HLO#ACIR HLO#ACIW HLO#ACON HLO#ACRD HLO#ACUP HLO#ADIS
    HLO#ADSC HLO#AEXT HLO#AFMT HLO#AFRR HLO#ALLO HLO#AMIN HLO#AOBP
    HLO#ASYS HLO#AUMX HLO#AUTO HLO#BCLR HLO#BCTC HLO#BIND HLO#BPRI
    HLO#BRS  HLO#BSQL HLO#BTMP HLO#BULD HLO#CARD HLO#CHKR HLO#CL
    HLO#CL64 HLO#CL7  HLO#CL8  HLO#CLLS HLO#CMTS HLO#CMTU HLO#CNTL
    HLO#CONT HLO#CPM  HLO#CPNT HLO#CPOL HLO#DB2V HLO#DCMD HLO#DISP
    HLO#DSAF HLO#DSPL HLO#DYNL HLO#ECIC HLO#EMCS HLO#EMIC HLO#EMID
    HLO#ENQS HLO#ENVF HLO#EPRI HLO#FCPY HLO#ICAI HLO#ICAL HLO#ICCC
    HLO#ICCI HLO#ICP7 HLO#ICP8 HLO#ICPO HLO#IDCF HLO#IDSA HLO#IERR
    HLO#IHSA HLO#IKPL HLO#IKPN HLO#ILGP HLO#ILRA HLO#ILRS HLO#ILSA
    HLO#INIT HLO#IOPF HLO#IPIE HLO#IPPB HLO#IPPC HLO#IPPD HLO#IPPH
    HLO#IPPL HLO#IPPN HLO#IPPS HLO#IRPL HLO#ISNA HLO#IX   HLO#IX10
    HLO#IX7  HLO#IX8  HLO#IX9  HLO#IXN8 HLO#IXP7 HLO#IXP8 HLO#IXP9
    HLO#IXPT HLO#JPRI HLO#LGAA HLO#LGAC HLO#LGAF HLO#LGAI HLO#LGAP
    HLO#LOGR HLO#LPIO HLO#LRD6 HLO#LRPT HLO#MAIN HLO#MDRV HLO#MEPL
    HLO#MLOG HLO#MMGR HLO#MPRI HLO#MREP HLO#MTIO HLO#OBEX HLO#OBRP
    HLO#OPCL HLO#OPRI HLO#OPVD HLO#OS   HLO#OUT2 HLO#PDEP HLO#PITS
    HLO#PLOG HLO#PRNG HLO#PRSE HLO#QSAM HLO#RANG HLO#RCFS HLO#RESM
    HLO#RH   HLO#RH10 HLO#RM24 HLO#RPRP HLO#RUNT HLO#SCHD HLO#SCPY
    HLO#SETP HLO#SETR HLO#SQLE HLO#STAT HLO#SUBD HLO#SUBX HLO#SYSC
    HLO#TABL HLO#TB   HLO#TB7  HLO#TB8  HLO#TBPT HLO#TP   HLO#TP10
    HLO#TS   HLO#TS10 HLO#TS7  HLO#TS8  HLO#TS9  HLO#TSS  HLO#TSSA
    HLO#TUTL HLO#UPRI HLO#UTED HLO#UTLL HLO#UTLS HLO#UTOB HLO#UTOP
    HLO#VERS HLO#VERT HLO#VSAM HLO#WRIT HLO#XMLC HLO#XMLD HLO#XMLI
    HLO#XMLS HLO#XMLU HLO$$PRM HLO$ACCS HLO$ACES HLO$ADM2 HLO$ADMN
    HLO$ADMS HLO$ALLC HLO$BCHJ HLO$BCPY HLO$BDSN HLO$BGDG HLO$BJBC
    HLO$BJBN HLO$BMSD HLO$BMSG HLO$BPRD HLO$BRST HLO$BULD HLO$BULJ
    HLO$BUT2 HLO$BUTA HLO$BUTB HLO$BUTC HLO$BUTD HLO$BUTE HLO$BUTG
    HLO$BUTH HLO$BUTI HLO$BUTJ HLO$BUTK HLO$BUTM HLO$BUTP HLO$BUTQ
    HLO$BUTR HLO$BUTS HLO$BUTT HLO$BUTU HLO$BUTV HLO$BUTX HLO$BUTZ
    HLO$CALL HLO$CHAR HLO$CRID HLO$CTCM HLO$DCVT HLO$DLOG HLO$DSET
    HLO$EDIT HLO$EDT2 HLO$EDTI HLO$EDTT HLO$EQRY HLO$EXPB HLO$EXPD
    HLO$EXPF HLO$FCOL HLO$IMPD HLO$IMPE HLO$IMPF HLO$INFO HLO$JBRK
    HLO$JOBD HLO$JOBR HLO$JOPT HLO$JOTM HLO$JOVR HLO$JPRC HLO$JPRD
    HLO$JPRJ HLO$JPRU HLO$LJBO HLO$LOBJ HLO$LPRD HLO$LSTP HLO$OINC
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R210 PSY UI65915

       UP19/10/23 P F910

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKRKK","label":"IBM Db2 Analytics Accelerator Loader for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
01 November 2019