Error description

  • Steps to reproduce:
    
    1.) Checkout DefectTracking OOTB schema and create a field.
    
    2.) Add the field to the form and using Radio button control.
    
    3.) Set the value to, for example: A & D
    
    Note: It is the value that has to be "A & D", this is in the
    extended tab of the radio button properties.
    
    4.) Check in the schema.
    
    You will see the following message:
    
    CRMMD1174E An unchanged schema cannot be checked in.
    Caught a CQException at the JNI Boundary:
    \bugbert.src\cqobjectmodel\cqschema.cpp: line 120-CRMMD1174E An
    unchanged schema cannot be checked in.
    
    Note: This behavior doesn't affect ClearQuest Windows/Classic
    Designer.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * ClearQuest Eclipse client                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When using an ampersand  for the value of Radio Button       *
    * control, a schema can't be checked in or saved in the        *
    * ClearQuest Eclipse client.                                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix is available in ClearQuest 9.0.1.10 and 9.0.2.2.
    ClearQuest Eclipse client was fixed to encode the string value
    of the Radio Button control so that it is XML safe.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH11134

  • Reported component name

    CLEARQUEST WIN

  • Reported component ID

    5724G3600

  • Reported release

    901

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-04-16

  • Closed date

    2020-08-24

  • Last modified date

    2020-08-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARQUEST WIN

  • Fixed component ID

    5724G3600

Applicable component levels

  • R901 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSSH5A","label":"Rational ClearQuest"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
24 November 2021