Error description

  • IMS PA Pre-Merge Copy of log input files was used to create a
    consolidated input file. When processing this consolidated input
    the End-of-File was not correctly detected, causing a subsequent
    read to fail with ABENDS337-04.                    ABEND337 S337
    
    This occurs after install of APAR PI36273 / UI26233, which is
    being marked PE (due to item #3 fix in that APAR).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Performance Analyzer V4.4       *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS PA log report job failed with       *
    *                      abend S337-04.                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    IMS PA Pre-Merge Copy of log input files was used to create
    a consolidated input file. When processing this consolidated
    input the End-of-File was not correctly detected, causing a
    subsequent read to fail with abend S337-04.
    

Problem conclusion

  • APAR PI36273/UI26233 introduced support for multi-volume
    non-extended  format Merge data sets. As part of this change
    at EOF of the original log input file the maximum volume
    sequence number was determined and stored in a work area. If
    the original input file consisted of only a single block of
    data, the code that read and stored the maximum volume
    sequence number was not entered. IMS PA uses this max volume
    sequence number in determining EOF of the Merge work file, in
    this case it was zero and resulted in an attempt to read beyond
    EOF. This is corrected and the maximum volume sequence number
    is determined and stored when a small input file is used as
    input to the Pre-Merge Copy process.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH10351

  • Reported component name

    IMS PERF ANALYZ

  • Reported component ID

    5655E1500

  • Reported release

    440

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-03-28

  • Closed date

    2019-05-06

  • Last modified date

    2019-06-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI62844

Modules/Macros

  •    IPISAPAR IPISMCOP
    

Fix information

  • Fixed component name

    IMS PERF ANALYZ

  • Fixed component ID

    5655E1500

Applicable component levels

  • R440 PSY UI62844

       UP19/05/10 P F905 Ø

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.4.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Performance Analyzer"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.4.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 June 2019