PH10278: IEC131I AND ABEND0C7 WHEN DB SENSOR PROCESSES HISAM DATABASES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • MSGIEC131I is issued and ABEND0C7 occurs in FABPHEXM when a DBD
    for a HISAM database with no overflow data set was generated by
    IMS version 1.2 and an HPIC job is run with HDPC=Y and SENSOR=Y
    for the HISAM database.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: The Stand-alone and Integrated FF Database   *
    *                 Sensor users who install the following       *
    *                 product and packs:                           *
    *                 - IBM IMS Database Reorganization Expert for *
    *                   z/OS V4.1 (FMID=H25N410)                   *
    *                 - IBM IMS Database Solution Pack for         *
    *                   V2.1 (FMID=HAHP210) or V2.2 (FMID=HAHP220) *
    *                 - IBM IMS Database Utility Solution for      *
    *                   V1.1 (FMID=HDFA110) or V2.1 (FMID=HDFA210) *
    ****************************************************************
    * PROBLEM DESCRIPTION: When DB Sensor processes HISAM          *
    *                      databases with no overflow data set and *
    *                      the DBDs were generated by IMS V1.2,    *
    *                      MSGIEC131I is issued.                   *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    When DBDs for HISAM databases with no overflow data set are used
    and the DBDs were generated by IMS V1.2, the following problems
    occurs:
    - When running HP Image Copy jobs with HDPC=Y and SENSOR=Y,
      MSGIEC131I is issued and ABEND0C7 occurs in FABPHEXM.
    - When running HP Image Copy jobs with HDPC=N and SENSOR=Y,
      MSGIEC131I, MSGBBE1407E, MSGBBE1452E, and MSGBBE1401E with
      FUNC=TERM RC=0008 are issued.
    - When running HP Pointer Checker jobs with SENSOR=YES,
      MSGIEC131I is issued and ABEND0C7 occurs in FABPMAIN.
    - When running stand-alone FF DB Sensor jobs, IMS Database
      Reorganization Expert jobs, or IMS Online Reorganization
      Facility jobs, MSGIEC131I, MSGBBE1404E, and MSGBBE1401E with
      FUNC=SCAN RC=0008 are issued.
    

Problem conclusion

  • The BBESCREB module has been modified to fix the errors.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH10278

  • Reported component name

    IMS DB REORG EX

  • Reported component ID

    5655F7400

  • Reported release

    410

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-03-28

  • Closed date

    2019-04-22

  • Last modified date

    2022-09-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI62588

Modules/Macros

  • BBESCREB
    

Fix information

  • Fixed component name

    IMS DB REORG EX

  • Fixed component ID

    5655F7400

Applicable component levels

  • R410 PSY UI62588

       UP19/04/23 P F904

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSVL5Q","label":"IMS Database Reorganization Expert for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.1.0","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
06 January 2023