A fix is available
APAR status
Closed as program error.
Error description
Delays in response from an ESM may result in the system going Short on Shortage (SOS) in high private LSQA 24bit storage. Resulting in abends, such as S878 and S80A. LSQA contains TCBs and parmlists for the ESM. CICS L8 TCBs are not disassociated from the task after being used for calling the ESM. Therefore, storage remains for the duration of the task. If there is a backlog of tasks, due to delays in ESM response time, then their combined storage usage can exceed the available LSQA.
Local fix
reduce SIT parm DSALIM
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users. * **************************************************************** * PROBLEM DESCRIPTION: Abends 80A and 878 after running out of * * LSQA. * **************************************************************** It is possible to suffer abend80A and abend878 when a large number of security calls are being issued to the External Security Manager (ESM). Each of the calls to the ESM use an L8 TCB. Each of these TCBs will use some LSQA storage which can eventually run out. The L8 TCB is being held for longer than the actual security call making the exhaustion of the LSQA more likely should the ESM suffer some sort of response slow down.
Problem conclusion
CICS has been changed to release the L8 TCB as soon as the security call has completed.
Temporary fix
Comments
×**** PE19/08/21 FIX IN ERROR. SEE APAR PH15917 FOR DESCRIPTION
APAR Information
APAR number
PH09914
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-03-19
Closed date
2019-07-25
Last modified date
2019-09-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI64408 UI64409 UI64410 UI64411
Modules/Macros
DFHDSAT DFHDSATT DFHDSATX DFHDSATY DFHXSAD DFHXSCT DFHXSDM DFHXSFL DFHXSIS DFHXSKR DFHXSLU DFHXSPW DFHXSRC DFHXSSB
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R000 PSY UI64411
UP19/07/26 P F907 ¢
R100 PSY UI64410
UP19/07/27 P F907 ¢
R200 PSY UI64408
UP19/07/26 P F907 ¢
R900 PSY UI64409
UP19/07/27 P F907 ¢
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: