PH09044: SYSTEM CRASH WITH A WAIT STATE CODE OF 014 OC4-11 IN DSNLFRCV+04BE, 0C4-04 IN DSNB1GET+09D6

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer experienced a WAIT014 system outage due to a CVT
    overlay with a linkage stack entry.  This occurred after
    shutting down the CQM monitor.  Root cause was determined to be
    module CQCTTEX1 using a pointer that unexpectedly contained an
    address of zero.  This resulted in incorrect data access leading
    to a wild branch in system key7.  Typically a wild branch will
    result in an ABEND0C1 or ABEND0C4.  In the customer's case the
    z/OS system trace table showed many ABEND0C1 errors being
    retried by Rocket Software FRR CQCMMFRR.  However a bad branch
    may also result in execution of data as an instruction, or may
    result in random instruction execution, with highly
    unpredictable results.  In this customer's case, data looking
    like a LCTL load control register instruction was executed,
    corrupting CR15 (which is used as a linkage stack pointer) such
    that it pointed to system CVT control block, leading to the CVT
    overlay the next time CR15 was used.
    .
    Also resolves the following:
    0C4-00000011 (DSNLFRCV+04BE)
    0C4-00000004 (DSNB1GET+09D6)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IBM Db2 Common Collector z/OS.      *
    ****************************************************************
    * PROBLEM DESCRIPTION: System crash with a wait state code     *
    *                      of 014 DBM1 started task spin loop      *
    *                                                              *
    *                      At the time of the system crash, a DB2  *
    *                      subsystem monitored by CQM was          *
    *                      processing dynamic SQL text while CQM   *
    *                      was shutting down from a 'P CQM'        *
    *                      request.                                *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF.                               *
    ****************************************************************
    System crash with a wait state code of 014
    DBM1 started task. spin loop
    
    The customer in this case experienced wait state code 14, but
    there can be other unpredictable system failures, such as
    system disablement.
    

Problem conclusion

  • The problem was triggered by zero address pointer to a CQM
    control block which caused a wild branch to execute
    unpredictable codes. The fix prevents this condition.
    
    Search Keywords:
    WAIT STATE, SPIN LOOP.
    

Temporary fix

Comments

  • ×**** PE19/06/10 FIX IN ERROR. SEE APAR PH13178  FOR DESCRIPTION
    

APAR Information

  • APAR number

    PH09044

  • Reported component name

    COMMON COLLECTO

  • Reported component ID

    5639OLC00

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-02-26

  • Closed date

    2019-03-15

  • Last modified date

    2019-07-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI61918

Modules/Macros

  • CQCMABA1 CQCMABB1 CQCMABC1 CQCMABC5 CQCMB2A1 CQCMB2B1 CQCMB2C5
    CQCMBNA1 CQCMBNB1 CQCMBNC5 CQCMBRA1 CQCMBRB1 CQCMBRC1 CQCMBRC5
    CQCMC1A1 CQCMC1B1 CQCMC1C1 CQCMC1C5 CQCMC2A1 CQCMC2B1 CQCMC2C1
    CQCMC2C5 CQCMCMA1 CQCMCMB1 CQCMCMC1 CQCMCMC5 CQCMCNA1 CQCMCNB1
    CQCMCNC1 CQCMCNC5 CQCMCOA1 CQCMCOB1 CQCMCOC1 CQCMCOC5 CQCMCRA1
    CQCMCRB1 CQCMCRC1 CQCMCRC5 CQCMCXA1 CQCMCXB1 CQCMCXC1 CQCMCXC5
    CQCMESA1 CQCMESB1 CQCMESC1 CQCMESC5 CQCMLCA1 CQCMLCB1 CQCMLCC1
    CQCMLCC5 CQCMLRA1 CQCMLRB1 CQCMLRC1 CQCMLRC5 CQCMPRA1 CQCMPRB1
    CQCMPRC1 CQCMPRC5 CQCMR1A1 CQCMR1B1 CQCMR1C1 CQCMR1C5 CQCMRLA1
    CQCMRLB1 CQCMRLC1 CQCMRLC5 CQCMRRA1 CQCMRRB1 CQCMRRC1 CQCMRRC5
    CQCMSIA1 CQCMSIB1 CQCMSIC1 CQCMSIC5 CQCMSRA1 CQCMSRB1 CQCMSRC1
    CQCMSRC5 CQCMT1A1 CQCMT1B1 CQCMT1C1 CQCMT1C5 CQCMTPA1 CQCMTPB1
    CQCMTPC1 CQCMTPC5 CQCMTRA1 CQCMTRB1 CQCMTRC1 CQCMTRC5 CQCMUGA1
    CQCMUGB1 CQCMUGC1 CQCMUGC5 CQCMZBA1 CQCMZBB1 CQCMZBC1 CQCMZBC5
    CQCTEDA1 CQCTEDB1 CQCTEDC1 CQCTEDC5 CQCTXLA1 CQCTXLB1 CQCTXLC1
    CQCTXLC5
    

Fix information

  • Fixed component name

    COMMON COLLECTO

  • Fixed component ID

    5639OLC00

Applicable component levels

  • R110 PSY UI61918

       UP19/03/20 P F903 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSHQZL","label":"IBM Db2 Data Access Common Collector for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2021