Error description

  • When running the DB2PE statistics report, message FPES0005W was
    issued. The problem may occur when processing IFCID001 and
    IFCID002 records generated by Db2 V9.
    
    The message text will be similar to the following:
    
    STATISTICS RECORD WITH IFCID 0002, SEQNO = xxxxxx MISSING.
    
    IFCID 0001, SEQNO = xxxxxx IGNORED.
    

Local fix

  • Apply PTF when available
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2 PM                *
    *                 users of component                           *
    *                 - Batch Reporter                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: When running the DB2PE Statistics       *
    *                      Report, message FPES0005W was issued.   *
    *                      The problem may occur when processing   *
    *                      IFCID001 and IFCID002 records generated *
    *                      by Db2 V9.                              *
    *                                                              *
    *                      The message text will be similar to the *
    *                      following:                              *
    *                                                              *
    *                      STATISTICS RECORD WITH IFCID 0002,      *
    *                      SEQNO = xxxxxx MISSING. IFCID 0001,     *
    *                      SEQNO = xxxxxx IGNORED.                 *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    Code may incorrectly check Db2 V9 IFCID002 for QBST, QBGL or
    QBSP overflow data sections. That should not be done for
    Db2 V9 and may cause IFCID001 and IFCID002 to not be paired
    correctly.
    

Problem conclusion

  • The reported problem was fixed.
    
    Search Keywords:
    BATCH STATISTICS REPORT FPES0005W IFCID002 DB2V9 MSGFPES0005W
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH08546

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-02-13

  • Closed date

    2019-04-02

  • Last modified date

    2019-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI62278

Modules/Macros

  • DGOSDLTD
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R520 PSY UI62278

       UP19/04/04 P F904

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]