Error description
When a subscription is created and run for the first time, it must start reading at some point in the log. That can result in some URs being split at the initial read point, so that the first records, including the BEGIN UR record, are missing. A missing BEGIN UR will be fabricated from data received in other records in the UR, however certain text content from the BEGIN UR will not be available. When this missing content is code page converted in preparation for being sent to the target, it can cause message CHC1517E to be issued with return code 4 and reason code 1.
Local fix
No local fix is available.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IIDR CDC for z/OS. * **************************************************************** * PROBLEM DESCRIPTION: When processing the first log records * * obtained after a subscription starts, * * some URs will necessarily be split, * * with only the latter half being read. * * IIDR constructs a BEGIN UR record to * * make such URs appear complete. These * * constructed BEGIN UR records have * * certain text fields that are not * * properly set to displayable characters. * * If the UR is subsequently being sent to * * the target, conversion of these text * * fields for Journal Control Fields can * * result in a UCS conversion error with * * return code 4 and reason code 1. * **************************************************************** * RECOMMENDATION: APPLY CORRECTIVE SERVICE * **************************************************************** A UCS conversion error with return code 4 and reason code 1 can occur when a subscription is started for the first time.
Problem conclusion
Constructed BEGIN UR records will have all their text fields filled with dash ("-") characters.
Temporary fix
Comments
APAR Information
APAR number
PH08422
Reported component name
INFO SRVR CDC Z
Reported component ID
5655U7600
Reported release
A21
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-02-13
Closed date
2019-02-15
Last modified date
2019-03-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI61316
Modules/Macros
CHCSTGSP
Fix information
Fixed component name
INFO SRVR CDC Z
Fixed component ID
5655U7600
Applicable component levels
RA21 PSY UI61316
UP19/02/20 P F902
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTVMA","label":"InfoSphere Data Replication for DB2 for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2.1","Edition":"","Line of Business":{"code":"","label":""}}]