IBM Support

PH08341: Lua optimmask abend using Lookup with multiple field definitions

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Lua optimmask abend using Lookup with
    multiple field definitions.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Optim for z/OS users of Lua and optimmask    *
    *                 lookup.                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Customer is using Lua optimmask to      *
    *                      invoke Optim Data Privacy               *
    *                      Provider Lookup.                        *
    *                      In some cases an ABEND may occur.       *
    *                                                              *
    *                      CEE3204S The system detected a          *
    *                         protection exception                 *
    *                         System Completion Code=0C4).         *
    *                         From compile unit at entry point     *
    *                      LServiceOdppRequest at statement 1931   *
    *                      compile unit  offset +00008EAC at entry *
    *                      offset +00008EAC at address 26802694.   *
    *                                                              *
    *                      Additionally, customers may see         *
    *                      incorrect column name is error report.  *
    ****************************************************************
    * RECOMMENDATION: Apply the provided fix.                      *
    ****************************************************************
    Depending on number,size and order of Lookup field definitions,
    memory could be corrupted.
    
    When Lua is used to set a column value such as:
    optim.target.setcolumnvalue("NON_CURRENT_COL_NAME",valueToSet)
    If an error occurs, the report will contain t
    he current column name
    (The column containing the Lua Procedure),
    rather than the column in error (in this example
    "NON_CURRENT_COLUMN_NAME")
    

Problem conclusion

  • Memory allocation was fixed.
    Column name has been correct during error reporting.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH08341

  • Reported component name

    OPTIM MOVE FOR

  • Reported component ID

    5655V0700

  • Reported release

    B70

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-02-08

  • Closed date

    2019-02-15

  • Last modified date

    2019-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FOPCFPMN FOPCXLIB FOPK10   FOPMCBMN FOPMCMMN FOPMCOLP FOPMDPRC
    FOPMDXTR FOPMECMN FOPMMCMR FOPMMJBS FOPMMUNU FOPMMUTL FOPRS10
    FOPRS3   FOPZFBMN FOPZFMMN FOPZSUB
    

Fix information

  • Fixed component name

    OPTIM MOVE FOR

  • Fixed component ID

    5655V0700

Applicable component levels

  • RB70 PSY UI61331

       UP19/02/20 P F902

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B70","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 March 2019