A fix is available
APAR status
Closed as program error.
Error description
Online Pointer Checker cannot report the number of free IOVF CIs correctly, in some cases. The field OPC had used in the past can no longer be relied on for an accurate count, so changes are being made as a result.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of Online Pointer Checker of HPFPU * * Fast Path Online Tools in Fast Path Solution * * Pack Version 1 Release 3 (FMID: HAHQ130). * **************************************************************** * PROBLEM DESCRIPTION: Online Pointer Checker (OPC) reports * * incorrect number of free IOVF CIs in * * some cases. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** The field in 2nd CI that OPC had used to report the number of free IOVF CIs can no longer be relied on for an accurate count.
Problem conclusion
OPC has been modified to scan the IOVF SMAP to report the correct number of free IOVF CIs.
Temporary fix
Comments
APAR Information
APAR number
PH07673
Reported component name
IMS FP SOLUTION
Reported component ID
5655W1400
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-01-23
Closed date
2019-02-07
Last modified date
2019-03-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI61192
Modules/Macros
FPXAPRC5 FPXAPRCB FPXAPRCC FPXAPRCD FPXAPRCE FPXAVSM0
Fix information
Fixed component name
IMS FP SOLUTION
Fixed component ID
5655W1400
Applicable component levels
R130 PSY UI61192
UP19/02/08 P F902
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]