Error description

  • When you drag the lifelines between sequence diagrams, the
    browser is updated, but the lifeline graphic is copied to the
    new diagram and the old graphic remains. If you undo this action
    you end up duplicating the original graphic.
    
    The correct behavior should be that drag and drop of life line
    should create a new one and leave the old one or remove the old
    one including its graphics.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Rhapsody                                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Sequence diagram lifelines are incorrectly duplicated after  *
    * drag/drop operation from Browser                             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed by fixing the drag & drop of life line in the browser.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH06977

  • Reported component name

    TLOGIC RHAPSODY

  • Reported component ID

    5724V74RP

  • Reported release

    830

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-01-07

  • Closed date

    2019-04-30

  • Last modified date

    2019-04-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC RHAPSODY

  • Fixed component ID

    5724V74RP

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS7P9W","label":"Rational Rhapsody"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"830","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
30 April 2019