Error description
When LIU is called in the DAI SOT for IMS catalog management of IMS Administration Tool, the following problems occur: 1. IMS catalog database space analysis was failed with FABX0507E DYNALLOC failed message. This problem occurs in the Administration Tool ISPF and the Management Console. 2. ?Show Full DBD List? or ?Show Full PSB List? was failed with 'An unidentified occurred'. This problem occurs in the Management Console.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: IMS Library Integrity Utilities for z/OS, * * Version 2 Release 2 (FMID=H27P220) users * * who use IBM IMS Administration Tool and * * the Catalog Manager utility. * **************************************************************** * PROBLEM DESCRIPTION: When LIU runs under IMS Administration * * Tool to show IMS Catalog Analysis, the * * following problems occur: * * * * - IMS Catalog database space analysis * * is failed with MSGFABX0507E when DBD * * library can not be discovered. * * - "Show Full DBD List" or "Show Full * * PSB List" in Program and Database * * Instances in IMS Catalog Databases is * * failed to identify ACBGEN timestamp * * when IMS catalog database contains an * * entry whose ACBGEN timestamp is null. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** When LIU is callied in the DAI SOT for IMS Catalog Analysis function of IMS Catalog and ACB management of the IMS Administration Tool, the following problems occur: - IMS Catalog database space analysis is failed with MSGFABX0507E when DBD library can not be discovered. This problem occurs both Web interface and ISPF interface. - "Show Full DBD List" or "Show Full PSB List" in the Program and Database Instances in IMS Catalog Databases is failed to identify ACBGEN timestamp when IMS catalog database contains an entry whose ACBGEN timestamp is null. In this case, Web interface of IMS Administration Tool shows the message "An unidentified error occurred.". This APAR fixes LIU not to dynamically allocate a DBD library when DBD library is not needed. If LIU can not allocate a DBD library, LIU issues MSGFABX0537E. This APAR also fixes LIU to show 'NO DATE' or 'NO TIME' when LIU is run for "Show Full DBD List" or "Show Full PSB List" and LIU finds ACBGEN timestamp which is saved in the IMS catalog database has null value. This APAR also fixes the following problem. When the user does not specify alphanumeric characters and special character like $, #, @, % and * for the parameter for keyword in FABXCIN control statement, it shows MSGFABX0521E SYNTAX ERROR IN THE CONTROL STATEMENT. This APAR modified to output another new message MSGFABX0528E.
Problem conclusion
The following modules have been modified to fix the problems: FABXADSC FABXATY0 FABXCAP1 FABXSTMP FABXWMT ======================== = DOCUMENTATION CHANGE = ======================== The documentation is modified as follows: ============================================================== IBM IMS Library Integrity Utilities for z/OS V2R2, User's Guide (SC19-3979-04) ============================================================== > Troubleshooting >> IMS Library Integrity Utilities messages >>> FABX messages << The following message is added. >> |FABX0528E THE PARAMETER FOR keyword MUST CONSIST ONLY OF |ALPHANUMERIC CHARACTERS, $, #, @, %, AND *. | |Explanation |The parameter specified for the indicated keyword |contains one or more unsupported characters. | |System action |The Catalog Manager utility ends with a return code of 8. | |User response |Correct the parameter and rerun the job. << The following message is modified. >> FABX0537E IMS CATALOG IS NOT DEFINED TO THE IMS. FABX0537E THE IMS MANAGEMENT OF ACBS IS NOT ENABLED. IMS DIRECTORY IS NOT DEFINED TO THE IMS. |FABX0537E [ACBLIB | DBDLIB] IS NOT DEFINED TO THE IMS. Explanation The reqested function requires the IMS catalog, IMS directory, |DBD library, or ACB library. However, none of these were found in the specified IMS subsystem. System action IMS Library Integrity Utilities ends with a return code of 12. User response Select the correct IMS ID.
Temporary fix
Comments
APAR Information
APAR number
PH06728
Reported component name
IMS LIBR INTEG
Reported component ID
5655I4200
Reported release
220
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-12-25
Closed date
2019-01-17
Last modified date
2019-03-19
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI60791
Modules/Macros
FABXADSC FABXATY0 FABXCAP1 FABXSTMP FABXWMT
Fix information
Fixed component name
IMS LIBR INTEG
Fixed component ID
5655I4200
Applicable component levels
R220 PSY UI60791
UP19/01/19 P F901
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89N","label":"IMS Library Integrity Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}}]