A fix is available
APAR status
Closed as program error.
Error description
CBL V6.1 Compiler changes required for Runtime IGZ0060W Message Truncation of high order digit positions; ok at CBL V4.2
Local fix
Problem with IGZXPR2 handling exponents less than -12. To work around the problem, change the COMPUTE statement to avoid the negative exponent. Example: the faulting code: 01 ANSWER PIC 9(1)V9(17) COMP-3. 01 TOT-ACTIV PIC 9(13)V9(2) COMP-3. PROCEDURE DIVISION. *==================* COMPUTE ANSWER = 10 ** -17 * TOT-ACTIV GOBACK. Work-around: Change the COMPUTE statement to avoid the negative exponent: COMPUTE ANSWER = 1 / 10 ** 17 * TOT-ACTIV
Problem summary
**************************************************************** * USERS AFFECTED: Enterprise COBOL V5.2 users running * * programs compiled with ARITH(COMPAT) that * * contain arithmetic expressions with the * * exponentiation operator (**), where both * * the base and exponent are numeric literals * * and the exponent is an integer less than -1. * **************************************************************** * PROBLEM DESCRIPTION: The exponentiation result might be * * incorrect. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** Given the following exponentiation in ARITH(COMPAT) mode, COMPUTE RESULT = BASE ** EXPONENT where - RESULT is a COMP-3(PACKED DECIMAL) data item - BASE is a fixed-point literal - EXPONENT is an integer literal less than -1 The COMPUTE result might be incorrect because an overflow occurred internally in the COBOL runtime.
Problem conclusion
The compiler was updated to generate the correct information required by the the COBOL runtime to perform the correct exponentiation calculation.
Temporary fix
Comments
APAR Information
APAR number
PH06109
Reported component name
ENT COBOL FOR Z
Reported component ID
5655W3200
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-12-04
Closed date
2018-12-12
Last modified date
2019-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCBE IGYCCBE IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYECWI IGYMSGE IGYMSGK IGYMSGT
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655W3200
Applicable component levels
R520 PSY UI60238
UP18/12/18 P F812
R521 PSY UI60239
UP18/12/19 P F812
R522 PSY UI60240
UP18/12/19 P F812
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: