IBM Support

PH05925: CLEARTOOL CRASH WITH CC901.5-RTC CMI INTEGRATION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When you are using the Rational ClearCase 9.0.1.5 cmi
    integration with Rational Team Concert, you may find that
    cleartool crashes.
    
    In the Microsoft Windows Event Viewer Application Log, you may
    see:
    
    Faulting application name: cleartool.exe, version: 9.105.0.160,
    time stamp: 0x5bc9f3d9
    Faulting module name: MSVCR100.dll, version: 10.0.40219.1, time
    stamp: 0x4d5f0c22
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of ClearCase change management integrations (CMI).     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * ClearCase change management integrations (CMI) could fail on *
    * Windows when connecting to a change management server with   *
    * an SSL certificate that expires in year 2038 or later.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix is available in ClearCase versions 9.0.1.9 and 9.0.2.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH05925

  • Reported component name

    CLEARCASE WIN

  • Reported component ID

    5724G2900

  • Reported release

    901

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-11-29

  • Closed date

    2020-03-30

  • Last modified date

    2020-03-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CLEARCASE WIN

  • Fixed component ID

    5724G2900

Applicable component levels

  • R901 PSY

       UP

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSSH27","label":"Rational ClearCase"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901"}]

Document Information

Modified date:
17 June 2021