IBM Support

PH05757: HCHECK FAILS, IRO0032E SERVICE FAILURE, SERVICE: BPEPOST FUNC=POST , RC=000000C, RSN=00000000

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • DRF/XF HCHECK periodically fails with
    IRO0032E SERVICE FAILURE, SERVICE: BPEPOST FUNC=POST ,
    RC=000000C, RSN=00000000
    Due to a timing problem, a BPE system ECB is double posted.
    The fix will create a unique ECB.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users using DRFXF HCHECK                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: When DRFXF initializes, a BPE           *
    *                      System ECB is double posted and         *
    *                      Function fails with RC=0C.              *
    ****************************************************************
    * RECOMMENDATION: Apply the fix to correct the issue.          *
    ****************************************************************
    A BPE system ECB is double posted
    during DRFXF initialization. This fix
    provides a unique ECB to bypass the issue.
    

Problem conclusion

  • A Unique ECB is created to circumvent the problem.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH05757

  • Reported component name

    IMS RCVR SOLUTN

  • Reported component ID

    5655V8600

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-11-26

  • Closed date

    2019-01-22

  • Last modified date

    2019-02-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI60858

Modules/Macros

  • IROMIDRC IROMIPRC IROMIREM IROMITOI IROMSREM
    

Fix information

  • Fixed component name

    IMS RCVR SOLUTN

  • Fixed component ID

    5655V8600

Applicable component levels

  • R210 PSY UI60858

       UP19/01/31 P F901

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
13 February 2019