Error description

  • After applying IMS V15 APAR PI83450, Library Integrity Checker
    abends in IMS HP Image Copy concurrent image copy (CIC) process.
     Because IMS HP Image Copy does not reflect the SVC number which
     defines in DFSIDEF0 on the control block.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS High Performance Image Copy for      *
    *                 z/OS Version 4 Release 2 users               *
    *                 ( FMID=H1J0420 )                             *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS HP Image Copy terminates with       *
    *                      system ABEND FFE ( ABENDFFE ) in IMS    *
    *                      V15 environment when the following      *
    *                      conditions are met.                     *
    *                      - IMS version 15 APAR PI83450 is        *
    *                        applied.                              *
    *                      - Customized type 2 supervisor call     *
    *                        (SVC) number is used.                 *
    *                      - Integrity Checker of IMS Library      *
    *                        Integrity Utilities (LIU) is          *
    *                        activated.                            *
    *                      - Batch Image Copy (IC) with            *
    *                        FALLBACK=Y or Concurrent Image Copy   *
    *                        (CIC) is requested.                   *
    *                      - Processed database are full function  *
    *                        databases except for HALDBs.          *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    IMS HP Image Copy terminates with system ABEND FFE ( ABENDFFE )
    in IMS V15 environment when the following conditions are met.
    - IMS version 15 APAR PI83450 is applied.
    - Customized type 2 supervisor call (SVC) number is used.
    - Integrity Checker of IMS Library Integrity Utilities (LIU) is
      activated.
    - Batch Image Copy (IC) with FALLBACK=Y or Concurrent Image
      Copy (CIC) is requested.
    - Processed database are full function databases except for
      HALDBs.
    
    By IMS APAR PI83450, type 2 SVC number can be defined in the
    IMS Installation Defaults module (DFSIDEF0) for Batch, DB/DC,
    DBCTL and DCCTL systems. IMS HP Image Copy does not refer the
    type 2 SVC number in DEFIDEF0 and it does not apply the correct
    number in the IMS control block. As the result, the default
    type 2 SVC number 254 ( X'FE') is used in the IMS process and
    the JOB gets the system abend FFE.
    

Problem conclusion

  • IMS HP Image Copy checks type 2 SVC number field in DFSIDEF0.
    When the type 2 SVC number is defined in the field, IMS HP
    Image Copy reflects it in the IMS control block.
    
    New message FABJ3974E ( MSGFABJ3974E ) and FABJ3943E
    ( MSGFABJ3943E ) have been added by this APAR.
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    The IBM IMS High Performance Image Copy for z/OS Version 4
    Release 2 User's Guide (SC19-2756-02). Updated documentation
    is available on:
    http://www-01.ibm.com/support/docview.wss?uid=swg27048732
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH04608

  • Reported component name

    IMS HP IMAGE CO

  • Reported component ID

    5655K9600

  • Reported release

    420

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-10-30

  • Closed date

    2018-11-13

  • Last modified date

    2018-12-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI59647

Modules/Macros

  • FABJDMP2 FABJDMP3 FABJDMP4 FABJDMP5 FABJDMP9 FABJDMPA FABJDMPB
    FABJFCC2 FABJFCC3 FABJFCC4 FABJFCC5 FABJFCC9 FABJFCCA FABJFCCB
    FABJIDEF FABJLINK FABJMAIN FABJMSGC
    

Fix information

  • Fixed component name

    IMS HP IMAGE CO

  • Fixed component ID

    5655K9600

Applicable component levels

  • R420 PSY UI59647

       UP18/11/15 P F811

Fix is available