IBM Support

PH03079: ABEND S0C4 IN GETJFCBDSNAME

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer is performing an EXTRACT using an IMAGE COPY on TAPE on
    z/OS 2.3.
    He receives the following ABEND S0C4:
    
    CEE3204S The system detected a protection exception (System
    Completion Code=0C4).
    From entry point GetJFCBDSName at statement 6528 at compile unit
    offset +000001BC at entry offset +000001BC at address 1BC9C6FC.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Optim for z/OS 2.3 users.                *
    ****************************************************************
    * PROBLEM DESCRIPTION: Customer is performing an EXTRACT using *
    *                      an IMAGE COPY on TAPE on z/OS 2.3.      *
    *                      The job is executing with SWA=ABOVE.    *
    *                      He receives the following ABEND S0C4:   *
    *                                                              *
    *                      CEE3204S The system detected a          *
    *                      protection exception (SystemCompletion  *
    *                      Code=0C4).                              *
    *                      From entry point GetJFCBDSName at       *
    *                      statement 6528 at compile unit          *
    *                      offset +000001BC at entry offset        *
    *                      +000001BC at address 1BC9C6FC.          *
    ****************************************************************
    Optim is incorrectly processing certain data set information
    when executing on z/OS 2.3 and the batch job has the SWA=ABOVE
    attribute.
    

Problem conclusion

  • Optim processing will be corrected to use the proper z/OS
    interfaces when executing while the batch job has the SWA=ABOVE
    attribute.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH03079

  • Reported component name

    OPTIM MOVE FOR

  • Reported component ID

    5655V0700

  • Reported release

    B70

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-09-20

  • Closed date

    2018-10-18

  • Last modified date

    2018-11-01

  • APAR is sysrouted FROM one or more of the following:

    PH03078

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FOP00003 FOP00103 FOP00203 FOP00303 FOP00B   FOP01B   FOP05B
    FOP07B   FOP08B   FOP09B   FOP0AB   FOP0BB   FOP0ITKA FOP1ODRV
    FOP1OSFN FOP3DTPR FOP4IPMN FOP4PEMN FOP4PMMN FOP4TRCE FOP9APIM
    FOP9GINF FOPCFPMN FOPCXLIB FOPHSTM  FOPIO    FOPMADDE FOPMAFCN
    FOPMAIN  FOPMAMAI FOPMARCN FOPMCDRT FOPMCENU FOPMCMAI FOPMCMMN
    FOPMCOFN FOPMCOLA FOPMCOLP FOPMDBMN FOPMDDDL FOPMDMAI FOPMDPRC
    FOPMDXTR FOPMECMN FOPMEMAI FOPMIXMM FOPMMCMN FOPMMCMR FOPMMJBS
    FOPMMUNU FOPMMUTL FOPMSELM FOPMTMDB FOPMUXIM FOPODPP  FOPOMN
    FOPRS3   FOPUMCBT FOPUUNLD FOPVOU   FOPZFBMN FOPZFMMN FOPZMAIN
    FOPZSUB
    

Fix information

  • Fixed component name

    OPTIM MOVE FOR

  • Fixed component ID

    5655V0700

Applicable component levels

  • RB70 PSY UI59230

       UP18/10/23 P F810

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B70","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 November 2018