Fixes are available
9.0.0.10: WebSphere Application Server traditional V9.0 Fix Pack 10
8.5.5.15: WebSphere Application Server V8.5.5 Fix Pack 15
9.0.0.11: WebSphere Application Server traditional V9.0 Fix Pack 11
9.0.5.0: WebSphere Application Server traditional Version 9.0.5 Refresh Pack
9.0.5.1: WebSphere Application Server traditional Version 9.0.5 Fix Pack 1
9.0.5.2: WebSphere Application Server traditional Version 9.0.5 Fix Pack 2
8.5.5.17: WebSphere Application Server V8.5.5 Fix Pack 17
9.0.5.3: WebSphere Application Server traditional Version 9.0.5 Fix Pack 3
8.5.5.20: WebSphere Application Server V8.5.5.20
8.5.5.18: WebSphere Application Server V8.5.5 Fix Pack 18
8.5.5.19: WebSphere Application Server V8.5.5 Fix Pack 19
8.5.5.16: WebSphere Application Server V8.5.5 Fix Pack 16
8.5.5.21: WebSphere Application Server V8.5.5.21
APAR status
Closed as program error.
Error description
ULB issues with Metric Server at V9.0 FP8 on Windows 2012. cpuload not accurate. After apply the WAS 9.0 ULB Fix Pack 8 fix pack on top of the Metric Server software. Tthe Windows Metric Server service will not start successfully. Issue with the process\code, no agent.log file is produced and Port 10004 is not opened.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: IBM WebSphere Application Server Load * * Balancer users using Metric Server on * * windows * **************************************************************** * PROBLEM DESCRIPTION: Metric server's cpuload program * * always responds with 100 when * * executed on Windows 2012. It takes a * * long time to respond also. * **************************************************************** * RECOMMENDATION: * **************************************************************** An old copy of cpuload.exe was being distributed.
Problem conclusion
Corrected the code to distribute the current copy of cpuload.exe. Also added cpuload.cmd and memload.cmd so that the scripts can be viewed and modified by the user (these are scripts on all other supported platforms). The windows code had a limitation where file extension must be provided if the script is not an exe file. Modified the code so that it will look for .bat and .cmd files when a .exe file is not found. Fix levels: 8.5.5.15 9.0.0.10
Temporary fix
Comments
APAR Information
APAR number
PH02089
Reported component name
WS EDGE LB IPV4
Reported component ID
5724H8812
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-08-23
Closed date
2018-08-28
Last modified date
2018-08-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WS EDGE LB IPV4
Fixed component ID
5724H8812
Applicable component levels
R850 PSY
UP
R900 PSY
UP
Document Information
Modified date: