A fix is available
APAR status
Closed as program error.
Error description
During log apply processing when DATA-MOVER is set to PGM(ADRDSSU) or PGM(EMCAPI), an IEC070I 209-220 error can occur when extending a target data set because candidate volumes are absent. Symptoms of this issue include: * IEC070I 209-220 error in the job log * Message CKZ52001E Subtask 01, Extend failed, rc X'00000008, rsn X'00D1DC0000000000, dsn ... After applying this fix, the IEC070I 209-220 error does not occur.
Local fix
Manually add candidate volumes to target data sets before running target job
Problem summary
**************************************************************** * USERS AFFECTED: Users of IBM Db2 Cloning Tool z/OS. * **************************************************************** * PROBLEM DESCRIPTION: During log apply processing when * * DATA-MOVER is set to PGM(ADRDSSU) or * * PGM(EMCAPI), an IEC070I 209-220 error * * can occur when extending a target data * * set because candidate volumes are * * absent. Symptoms of this issue include: * * * IEC070I 209-220 error in the job log * * * Message CKZ52001E Subtask 01, * * Extend failed, rc X'00000008, * * rsn X'00D1DC0000000000, dsn ... * * After applying this fix, the IEC070I * * 209-220 error does not occur. * **************************************************************** * RECOMMENDATION: APPLY the PTF. * **************************************************************** Code has been changed to correct this condition.
Problem conclusion
APPLY the PTF.
Temporary fix
Comments
APAR Information
APAR number
PH02002
Reported component name
DB2 CLONING TOO
Reported component ID
5655N1000
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-08-21
Closed date
2018-09-11
Last modified date
2018-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
CKZ00620
Fix information
Fixed component name
DB2 CLONING TOO
Fixed component ID
5655N1000
Applicable component levels
R320 PSY UI58442
UP18/09/14 P F809
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAUUE","label":"IBM Db2 Cloning Tool for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]