A fix is available
APAR status
Closed as program error.
Error description
Using IMS E4D DDL for a FP DBD and importiia copybook results in FPSI with a XDFLD coding that has PSELOPT=M. But the corequisite keyword PSELRTN is not coded. If PSELRTN is not coded or omitted then PSELOPT=M should not be generated. When using IMS E4D DDL importing a copybook for a DEDB a DEPENDSON= keyword is included. DEPENDSON= is valid when a NAME= of a field is coded. If the copybook is excluded then the error doesn't occur.
Local fix
Omit the copybook when doing the IMS E4D DDL process.
Problem summary
**************************************************************** * USERS AFFECTED: * * IMS V15 users of DBDGEN with large number of external fields * * defined in DBD source. * **************************************************************** * PROBLEM DESCRIPTION: * * If DBD contains large number of external fields and one of * * the external field is referenced on DEPENDSON= then DBDGEN * * fails with FLD630 during the validation of DEPENDSON. * **************************************************************** * RECOMMENDATION: * * INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** During the validation of DEPENDSON field, the logic prematurely exits after 255 loops thus could not find external field in the DBD with large number of external fields.
Problem conclusion
FIELD macro changed to use variable that keeps the count of fields/external fields in the DBD instead of hard coded value.
Temporary fix
Comments
APAR Information
APAR number
PH01972
Reported component name
IMS V15
Reported component ID
5635A0600
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-08-21
Closed date
2018-09-19
Last modified date
2018-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI58584
Modules/Macros
FIELD
Fix information
Fixed component name
IMS V15
Fixed component ID
5635A0600
Applicable component levels
R500 PSY UI58584
UP18/09/24 P F809
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSEPH2","label":"IMS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"15","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
22 December 2023