Error description
Near Term History Distributed Database statistics may show incorrect time interval for when Queued DBATs occurred. Select H for Near Term History Select A for Statistics Zoom (PF11) an interval Enter E for Distributed database Screen ZHDFD is displayed Start and End time for the interval may be incorrect for when the amount of Queud DBATs occurred. Other Keywords DISTRIBUTED DATA FACILITY STATISTICS DETAIL NTA NTH DBAT cued
Local fix
Apply PTF when available Use batch reporting against SMF if available
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2 PM * * users of component * * - Near Term History * * - Classic Interface * **************************************************************** * PROBLEM DESCRIPTION: The DBAT Queued count on Classic panel * * HDFD are not showing in the intervals * * they occurred. * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** The start and end time for the NTH statistics interval was not calculated correctly causing DBAT Queued event being placed in a wrong statistics time interval.
Problem conclusion
Corrected the start and end time for a distributed data facility NTH statistics time interval. Search Keywords: INCORROUT DBAT QUEUED NTH STATISTICS INTERVAL ZHDFD SMF
Temporary fix
Comments
APAR Information
APAR number
PH01386
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
540
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-08-06
Closed date
2018-10-12
Last modified date
2018-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI59083
Modules/Macros
KO2CSTBB KO2HDFSH KO2ODSTB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R540 PSY UI59083
UP18/10/14 P F810
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.4.0"}]
Document Information
Modified date:
30 March 2021