Error description
An IMS shutdown wait is due to an INUSE lock on the CCB by QCF. The two suspect waiting SAVE AREA flows are: DFSICIO0 -> N256163 -> DFSCVEA2 -> DFSNCLY0 -> DFSNCLZ0 -> NCLZSIGN -> DFSNCS20 -> DFSUSE00 -> DFSISERW and IQCCCVC0 -> CCVC2000 -> CCVC3200 -> CCVC4000 -> IQCQMRQ0 -> QMRQCMDS -> IQCQMR50 -> IQCQMR50-AT-MR5CONV -> DFSCONX0 -> UNK -> DFSUSE00 -> DFSISERW -> The SLU2 dynamic terminal is hung in signoff processing waiting for a LOCK on the NODE/USER structure so the blocks could be deallocated. A QCF task terminated earlier while still holding an INUSE on the terminal. QCF attempted to release the INUSE, but the request failed due to an invalid workid passed on the INUSE. This residual INUSE causes the LOCK request to WAIT indefinitely resulting in the terminal hang. The only way to clear the hang is to recycle IMS.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of QCF 3.2 * **************************************************************** * PROBLEM DESCRIPTION: An IMS shutdown wait is due to an INUSE * * lock on the CCB by QCF. * * The two suspect waiting SAVE AREA * * flows are: * * DFSICIO0 -> N256163 -> DFSCVEA2 -> * * DFSNCLY0 -> DFSNCLZ0 -> NCLZSIGN -> * * DFSNCS20 -> DFSUSE00 -> DFSISERW * * and * * IQCCCVC0 -> CCVC2000 -> CCVC3200 -> * * CCVC4000 -> IQCQMRQ0 -> QMRQCMDS -> * * IQCQMR50 -> IQCQMR50-AT-MR5CONV -> * * DFSCONX0 -> UNK -> DFSUSE00 -> * * DFSISERW -> * * * * The SLU2 dynamic terminal is hung in * * signoff processing waiting for a LOCK * * on the NODE/USER structure so the * * blocks could be deallocated. A QCF * * task terminated earlier while still * * holding an INUSE on the terminal. QCF * * attempted to release the INUSE, but the * * request failed due to an invalid workid * * passed on the INUSE. This residual * * INUSE causes the LOCK request to WAIT * * indefinitely resulting in the terminal * * hang. The only way to clear the hang is * * to recycle IMS. * **************************************************************** * RECOMMENDATION: Install the APAR to avoid IMS wait on shut * * down. Recycle the control region to get the * * changes. * **************************************************************** The SLU2 dynamic terminal is hung in signoff processing waiting for a LOCK on the NODE/USER structure so the blocks could be deallocated. A QCF task terminated earlier while still holding an INUSE on the terminal. QCF attempted to release the INUSE, but the request failed due to an invalid workid passed on the INUSE. This residual INUSE causes the LOCK request to WAIT indefinitely resulting in the terminal hang. The only way to clear the hang is to recycle IMS.
Problem conclusion
Install the APAR to avoid IMS wait on shut down. Recycle the control region to get the changes.
Temporary fix
Comments
APAR Information
APAR number
PH00915
Reported component name
IMS QUEUE CNTL
Reported component ID
5697E9900
Reported release
320
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-07-25
Closed date
2018-11-30
Last modified date
2019-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI60020
Modules/Macros
IQCCCVCD IQCCCVCE IQCCCVCF IQCQMR5D IQCQMR5E IQCQMR5F IQCQMRAD IQCQMRAE IQCQMRAF
Fix information
Fixed component name
IMS QUEUE CNTL
Fixed component ID
5697E9900
Applicable component levels
R320 PSY UI60020
UP18/12/07 P F812
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A6","label":"IMS Queue Control Facility"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"320","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 January 2019