Error description

  • The KEYLEN parameter on DB PCB macro defines the length of the
    key feedback area allocated in the PCB.  When ACBGEN (BUILD
    PSB) is run, the KEYLEN specification is checked on each PCB to
    make sure that the longest concatenated key for a hierarchic
    path of sensitive segments can be stored within the key
    feedback area of that length.  When SUBSEQ fields (/CK..) are
    used in DEDB FPSI, ACBGEN is not calculating the correct KEYLEN
    requirement.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IMSFP V15 Fast Path secondary index (FPSI) users             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * For DEDB that is accessed through its Fast Path secondary    *
    * index (PROCSEQD=) which has SUBSEQ= defined in the SRCH      *
    * fields,  ACBGEN does not include the length of SUBSEQ fields *
    * in the pointer key length for the  minimum required KEYLEN=  *
    * checking.  This may cause the key feedback area that is      *
    * obtained not long enough when the longest physical key       *
    * length accessed thru the primary key is shorter than the     *
    * logical key lemgth accessed thru the secondary index key.    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * INSTALL CORRECTIVE SERVICE FOR APAR/PTF                      *
    ****************************************************************
    Additional Symptoms when ACBGEN finds KEYLEN specified is too
    short:
     DFS0919I  PSB --psbname  -- PCB --dedbname-- KEYLEN SPECIFIED
    TOO SMALL.  KEYLEN SHOULD BE --nnnnn BYTES
     DFS0587I  ERROR BUILDING PSB=psbname   - IT WILL BE DELETED
    FROM ACBLIB.    ***************** E R R O R *******************
    

Problem conclusion

  • Routine CMPKEYLN in DBFDLB00 and DBF3BB00 have been modified to
    use the pointer key length that includes SUBSEQ fields in its
    calculation to compute the minimum required KEYLEN= for DEDB
    with PROCSEQD= defined.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH00772

  • Reported component name

    IMS V15

  • Reported component ID

    5635A0600

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-07-20

  • Closed date

    2018-08-02

  • Last modified date

    2018-09-04

  • APAR is sysrouted FROM one or more of the following:

    PH00723

  • APAR is sysrouted TO one or more of the following:

    UI57652

Modules/Macros

  • DBFDLB00 DBF3BB00
    

Fix information

  • Fixed component name

    IMS V15

  • Fixed component ID

    5635A0600

Applicable component levels

  • R500 PSY UI57652

       UP18/08/04 P F808

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.