Error description
After applying APAR OW36991, when processing an ISQSTOP command the system receives an 0C4 ABEND. The message received is: DSI172I SUBTASK 'xxxxxxx' ABENDED WITH CODE X'0C4000' CNM998E ABEND/LOGOFF WHILE RUNNING COMMAND PROCEDURE ISQSTOP
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All System Automation for OS/390 Processor * * Operations users. V1R3 and V1R2 * **************************************************************** * PROBLEM DESCRIPTION: Abend System 0C4 (S0C4) while running * * ISQSTOP. Can also occur in ISQSTRT if * * the ISQSTART fails to complete. * * V1R3 only: APAR OW37667 PTF UW60628 * * ships a JCLIN which may not inlude new * * modules introduced by APAR OW36991 PTF * * UW60373. APAR OW36991 PTF UW60373 ships * * a JCLIN which may not inlude new * * modules introduced by APAR OW37667 PTF * * UW60628. * **************************************************************** * RECOMMENDATION: * **************************************************************** ABEND S0C4 in ISQSTOP (csect ISQATBF) during ProcOps shutdown. V1R3 only: The expected below the line storage relief may not be obtained if OW37667/UW60628 is applied after OW36991/UW60373. Applying OW36991/UW60373 after OW37667/UW60628 may result in unresolved external references.
Problem conclusion
ISQATBF (commands ISQSTOP and ISQSTART) has been changed to only look at the saved copy of the trace flag so that it does not reference the original trace flag after freeing the control block which contains it. V1R3 only: JCLIN has been updated to include all new modules from OW37667/UW60628 and OW36991/UW60373 both of which are SUPerceded by this APAR.
Temporary fix
fixtest given to customer
Comments
APAR Information
APAR number
OW40914
Reported component name
TSCF
Reported component ID
568813901
Reported release
A30
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1999-09-07
Closed date
1999-10-04
Last modified date
1999-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UW63860 UW63910
Modules/Macros
HKYSA30J ISQAFREE ISQAFREM ISQAGET ISQAGETM ISQATBF ISQATBL ISQCCMDS ISQCCRPL ISQCDELI ISQCLIST ISQCMMT ISQCOMM ISQCPASS ISQCPOLL ISQCPTM ISQCPURQ ISQCQUE ISQCRSYN ISQCSSES ISQCSTOR ISQGPOLL ISQIXDST ISQSTOP ISQSTRT ISQZEND ISQZMMT ISQZOPT ISQZPOLL ISQZPTF ISQZXDST
Fix information
Fixed component name
SYS AUTO OS/390
Fixed component ID
565513700
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A30","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A30","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 November 1999