OW25577: AFTER A VTAM STOP/RESTART, THE CDRM IS IN PACDR STATUS. ABEND0C4OCCURS IN ISTTSCXI ON THE OTHER VTAM THAT IS CONNECTED BY CTC.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • VTAM-A and VTAM-B are connected by ESCON CTCA.
    First, both CDRMs are active status. One VTAM(ex. VTAM-A) is
    stopped and restarted. Then abend0c4 occurs in module ISTTSCXI
    on the other side VTAM(VTAM-B) and the cdrm of VTAM-A is in
    PACDR status on VTAM-A. It's still in INACT status on VTAM-B.
    Abend0c4 occurs at offset x'e52' in module ISTTSCXI(96.331) that
    was called by ISTPUCRT. The failing instruction is 'BA8A,E290'.
    Due to null reg14 r14 which was loaded from ICNCB(reg9) + 46C.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All using CTC connections.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C4 ISTTSCXI during INOP           *
    *                      processing for a CTC connection.        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Code was added to take diagnostic dumps should an INOP occur on
    MPC or AHHC connection.  Modules ISTTSCXI and ISTTSCXR are
    among the modules which have coded added for this purpose.
    These modules are are also called for basic CTC connections.
    The diagnostic dump enhancements stored information in the
    MPNCB which was referenced via the CPNMPNCB pointer.  In a
    basic CTC connection this field is zero, which results in the
    ABEND0C4.  The ABEND0C4 could show up in ISTTSCXI or ISTTSCXR
    depending on which module INOPed the connection.
    

Problem conclusion

  • Modules ISTTSCXR and ISTTSCXI have been corrected to check the
    XCNSNACP is on prior to storing data into the MPNCB.
    ISTTSCXE has been included for maintenance purposes.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OW25577

  • Reported component name

    VTAM V4 MVS/ESA

  • Reported component ID

    569511701

  • Reported release

    401

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1997-02-28

  • Closed date

    1997-03-17

  • Last modified date

    1997-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UW37005

Modules/Macros

  • ISTTSCXE ISTTSCXI ISTTSCXR
    

Fix information

  • Fixed component name

    VTAM V4 MVS/ESA

  • Fixed component ID

    569511701

Applicable component levels

  • R401 PSY UW37005

       UP97/04/09 P F704

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"401","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCY4DZ","label":"DO NOT USE"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"401","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 May 1997