APAR status
Closed as documentation error.
Error description
AFTP always returns a successful completion code ( zero 0 ) , even if the job fails. This makes it difficult to invoke AFTP from a batch program, as the return code always indicates it was successful when it may have failed.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: APPC Application Suite users. * **************************************************************** * RECOMMENDATION: * **************************************************************** When exiting, the AFTP function always returns with a return code of success (RC=0), even if a file transfer operation (or any AFTP command) failed while in the AFTP command environment.
Problem conclusion
While inside the AFTP command interface, any number of commands can be executed. A user may misspell the name of a directory while changing the current working directory, which would fail. The user may then correctly change the current working directory, and then proceed to misspell the name of the file to be sent. Finally, after correcting the name of the file, the file transfer succeeds. Since there is no practical way to concatenate return codes or merge them, the function will continue to return a positive return code on exit. This return code signifies only that the AFTP environment was entered and exited. If a return code from a file transfer is needed, the user should be using the command line interface, acopy. The acopy return code reflects the success (or failure) of the file transfer. This would be appropriate for users executing file transfers from a batch job. The following text will be added to the APPC Application Suite User's Guide (SC31-6532-00): Chapter 5. APPC File Transfer Protocol(AFTP) Section: "Using the Interfaces: Command Line versus Command Environment" -Add a new line to the Table as follows: Function acopy Command AFTP command Environment ---------------------------------------------------------- Return Code reflecting yes no outcome of command -Add a new paragraph at end of section as follows: Note: The AFTP command Environment on exit always gives a successful return code. The acopy command return code is based on the success or failure of the file transfer, making it more appropriate for execution from a batch job.
Temporary fix
Comments
APAR Information
APAR number
OW15157
Reported component name
VTAM V4 MVS/ESA
Reported component ID
569511701
Reported release
204
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1995-08-23
Closed date
1995-09-21
Last modified date
1995-09-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
| SCSI653200 |
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"204","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCY4DZ","label":"DO NOT USE"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"204","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: