A fix is available
APAR status
Closed as program error.
Error description
Users are unable to successfully connect to an AFTPD server on an MVS host. Customer successfully ran the APPFTPAJ job to issue the TPADD to define the AFTPD tpname to MVS/APPC. The AFTP client receives message: Problem detected by the client. APP0202E The APPC conversation failed. The MVS console shows the following information when the AFTPD server is initiated: CSV003I REQUESTED MODULE IBMBLIIA NOT FOUND CSV028I ABEND806-04 JOBNAME=AFTP STEPNAME=RUNAFTP IEA995I SYMPTOM DUMP OUTPUT SYSTEM COMPLETION CODE=806 REASON CODE=00000004 TIME=08.48.25 SEQ=00007 CPU=0000 ASID=001C PSW AT TIME OF ERROR 070C1000 81038CBE ILC 2 INTC 0D NO ACTIVE MODULE FOUND NAME=UNKNOWN DATA AT PSW 01038CB8-9C4C181B 0A0D18FB 180C181D GPR 0-3 00001400 84806000 00000000 00FD4368 GPR 4-7 000000FF 008FF7B0 00000004 0000000C GPR 8-11 008C4C50 81038418 01039417 84806000 GPR 12-15 00FD4368 008C4C50 81038C56 00000004 END OF SYMPTOM DUMP The AFTP error log records the following error (APPFTPE): ------------------------------------------------------- Error Log For Program : "AFTP" APPC File Transfer Prog Program Version Number: 1.0 Program Log Entry Time: Wed Aug 23 12:48:27 1995 Displayed message: Problem detected by the client. APP0202E The APPC conversation failed. Service details: APP0235E CPIC return code: 26, CM_RESOURCE_FAILURE_NO_RETRY APP0235E CPIC Verb: CMRCV, Receive APP0235E Partner LU name: MVSLU01A APP0235E Mode name: #BATCH File name : $Workfile: appzcobc.c Line number : 4806 Additional Symptoms: IBMBLIAA - Using C/370 CEEBINIT - Using LE/370
Local fix
Add a STEPLIB DD card in job APPFTPAJ to point to the C RUNTIME libraries: //STEPLIB DD DSN=sedclink,DISP=SHR // DD DSN=sibmlink,DISP=SHR This STEPLIB statement is already coded in job APPPTPAJ to define APINGD. Alternatively, you can add the C RUNTIME libraries in LINKLST. Note: If running LE/370, DSN=sceerun
Problem summary
**************************************************************** * USERS AFFECTED: All APPC Application Suite AFTP users. * **************************************************************** * PROBLEM DESCRIPTION: ABEND 806 after attempting to connect * * to a server within the AFTP command * * environment. * **************************************************************** * RECOMMENDATION: * **************************************************************** The sample JCL file (APPFTPAJ) which issues the TPADD to APPC/MVS for the AFTP server is missing the STEPLIB statements which include the location of the C Runtime libraries.
Problem conclusion
Sample JCL file APPFTPAJ was modified to include the STEPLIB statements needed to specify the location of the C Runtime libraries. Sample JCL file APPZMSCJ was modified to include comments clarifying what needs to be changed before it is submitted.
Temporary fix
Comments
APAR Information
APAR number
OW15120
Reported component name
VTAM V4 MVS/ESA
Reported component ID
569511701
Reported release
204
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
1995-08-23
Closed date
1995-09-27
Last modified date
1995-11-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UW21719 UW21720
Modules/Macros
APPFTPAJ APPZMSCJ
Fix information
Fixed component name
VTAM V4 MVS/ESA
Fixed component ID
569511701
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"204","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCY4DZ","label":"DO NOT USE"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"204","Edition":"","Line of Business":{"code":"","label":""}}]