IBM Support

OW00895: DEVICE ADDRESSES IN THE FORMAT '0XXX' ARE INCORRECT ON DISPLAY OF A CHANNEL ATTACHED MAJOR NODE.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • 'DISPLAY ID=' output only contains the last three digits of the
    CUA for addresses specified as ADDRESS=0xxx when displaying
    channel attached devices.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All using ADDRESS=0xxx in a CA major node    *
    *                 (VBUILD TYPE=CA).                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: IST232I on the DISPLAY of a Channel     *
    *                      Attached major node (VBUILD TYPE=CA)    *
    *                      when ADDRESS=0xxx was specified on      *
    *                      the LINE definition statement shows     *
    *                      CUA=xxx instead of CUA=0xxx.            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    ADDRESS=0xxx was specified on the LINE definition statement
    in a Channel Attached major node (VBUILD TYPE=CA). When
    displaying the major node, MSGIST232I shows CUA=xxx instead
    of CUA=0xxx.
    

Problem conclusion

Temporary fix

Comments

  • *********
      * HIPER *
      *********
    Module ISTNOCDI has been changed to display CUA=0xxx on
    message IST232I when the Channel Attached major node is
    displayed when ADDRESS=0xxx was specified on the LINE
    definition statement.
    

APAR Information

  • APAR number

    OW00895

  • Reported component name

    VTAM V4 MVS/ESA

  • Reported component ID

    569511701

  • Reported release

    101

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1993-12-08

  • Closed date

    1994-01-07

  • Last modified date

    1994-07-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UW01945

Modules/Macros

  • ISTNOCDI
    

Fix information

  • Fixed component name

    VTAM V4 MVS/ESA

  • Fixed component ID

    569511701

Applicable component levels

  • R101 PSY UW01945

       UP94/04/18 P F404 Ž

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"101","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCY4DZ","label":"DO NOT USE"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"101","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: