IBM Support

OA68075: FOLLOWING ANY ABEND, TASK CLOSE GOES INTO A LOOP IN IFG0TC0A ATTEMPTING TO SEARCH FOR A DEB

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After an abend occurs, task close enters a loop in IFG0TC0A at
    UJ97283. Loop is in IFG0TC2B procedure in label DEBDCHN1 from
    +x'1990' to x'1AA4'.
    IFG0TC0A at base the loop is from x'1980' to x'1A94'.
    IFG0TC0A in an infinite loop while holding the local lock and
    searching for a DEB.
    additional symptoms:
    This issue has been seen following an abend878, abend837
    abendB37 and abend0C4.
    The abend can be any code, in any module that will cause task
    close to go into this loop (on 3.2 only).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users of zOS 3.2                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: A loop occurs when CLOSE issues an      *
    *                      ABEND and CLOSE was issued by task      *
    *                      termination.                            *
    *                                                              *
    *                      Users also reported an ABEND878-4.      *
    ****************************************************************
    

Problem conclusion

  • The problem has been corrected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA68075

  • Reported component name

    DATA MGMT SUPPO

  • Reported component ID

    5695DF107

  • Reported release

    320

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-06-16

  • Closed date

    2025-07-08

  • Last modified date

    2025-10-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ97555

Modules/Macros

  • IFG0TC0A
    

Fix information

  • Fixed component name

    DATA MGMT SUPPO

  • Fixed component ID

    5695DF107

Applicable component levels

  • R320 PSY UJ97555

       UP25/07/29 P F507

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.