Error description

  • When a Connection.readGeneric() is issued on an empty VSAMDB, a
    bit is set (resultToken) to indicate that it is an empty DB in
    the ResultSet. However, when a next() is issued against the
    ResultSet to iterate to the next document in the DB, the empty
    DB condition is not checked, which causes a generic
    EzNoSQLException with a RC of 65535 and the following message:
    
    znsq_last_result Report  2025.084 08:25:55
    
    API Name: znsq_position       RC: 00000008  RS: 8210008A
    
    
    Diagnostic Data:
    
    
    RPLFDBWD: 09080010
    

Local fix

  • Avoid calling next() on an empty DB
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All VSAM RLS users using EzNoSQL Java APIs  *
    *                 an ordered index database.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Issuing a ResultSet.next() against an   *
    *                      empty database positioning will         *
    *                      generate an unknown return code 65535.  *
    *                      The positioning is allowed but only     *
    *                      to initiate document inserts.           *
    ****************************************************************
    

Problem conclusion

  • EzNoSQL Java will detect the presence of an empty ordered
    database and throw an IllegalStateException.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA67663

  • Reported component name

    VSAM REC LEV SH

  • Reported component ID

    5695DF122

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-03-25

  • Closed date

    2025-07-30

  • Last modified date

    2025-10-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ97755 UJ97756 UJ97757

Modules/Macros

  • IGWVRJAR IGWVRPSJ
    

Fix information

  • Fixed component name

    VSAM REC LEV SH

  • Fixed component ID

    5695DF122

Applicable component levels

  • R250 PSY UJ97755

       UP25/09/04 P F509

  • R310 PSY UJ97756

       UP25/09/04 P F509

  • R320 PSY UJ97757

       UP25/09/04 P F509

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"310"}]

Document Information

Modified date:
21 October 2025