A fix is available
APAR status
Closed as program error.
Error description
When using a provider name of at least 8 characters and an lrecl over 104 for OBJNAME, an extra space is added at the end of the provider name and the .json, causing CDA to not find it;e.g. ERROR: Could not open provider file </usr/lpp/dfsms/gdk/providers/DSSCLOUD .json> ERROR: Errno message (129): EDC5129I No such file or directory.
Local fix
1) Use an OBJNAME that has lrecl of 104 or less. 2) If long OBJNAME is needed, just split it multiple records (104 or less) using OBJNAMEX instead
Problem summary
**************************************************************** * USERS AFFECTED: Users of z/OS V2R5 DFSMSdfp CDA and above * * using GDKUTIL with cloud provider name * * with at least 8 characters. * **************************************************************** * PROBLEM DESCRIPTION: Users of GDKUTIL would find that their * * specified provider name from the * * PROVIDER keyword would get a trailing * * blank character to the name, causing * * RC 110 GDK_PROVIDER_OPEN_FAILURE. * **************************************************************** GDKWRITE API returns GDK_PROVIDER_OPEN_FAILURE when using a provider file name at least 8 characters long.
Problem conclusion
DFSMSdfp CDA GDKUTIL has been modified to correct the problem. KEYWORDS: DFSMSCS/K
Temporary fix
Comments
APAR Information
APAR number
OA67596
Reported component name
CLOUD DATA ACCE
Reported component ID
5695DF124
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-03-03
Closed date
2025-05-15
Last modified date
2025-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ97186 UJ97188 UJ97189
Modules/Macros
GDKUTILJ
Fix information
Fixed component name
CLOUD DATA ACCE
Fixed component ID
5695DF124
Applicable component levels
R250 PSY UJ97189
UP25/05/31 P F506
R310 PSY UJ97188
UP25/06/03 P F506
R320 PSY UJ97186
UP25/05/31 P F506
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"310"}]
Document Information
Modified date:
02 July 2025