A fix is available
APAR status
Closed as program error.
Error description
CONTROL UNIT(nnnn) CLEARFENCE SERIAL(volser) SCOPE(DEV) -ALL is issued in 3.1 system and fails with ICK30713I UNABLE TO ALLOCATE UCB, RC=0008, RSN=0004 FROM IOSODS ICK31024I UNABLE TO OPEN VOLUME ICK30003I FUNCTION TERMINATED. CONDITION CODE IS 12 This occurs if the volume is soft-fenced. Same command issued in 2.5 is successful and clears the soft fence. Additional Symptoms:MSGICK30713I RC08 RSN04 RC8 RSN4
Local fix
Run command on system lower than 3.1.
Problem summary
**************************************************************** * USERS AFFECTED: All users who issue ICKDSF CONTROL * * parameter to a soft fenced device on * * D/T2107 storage systems. * **************************************************************** * PROBLEM DESCRIPTION: ICKDSF CONTROL's invocation of IOSODS * * does not complete successfully for * * soft fence device. * **************************************************************** ICKDSF CONTROL CLEARFENCE calls IOS Offline Device Service (IOSODS) which terminated due to soft fenced device. IOSODS should complete successfully for a soft fenced device and allow ICKDSF CONTROL CLEARFENCE to clear the soft fence condition.
Problem conclusion
ICKDSF CONTROL completes successfully with soft fenced device. ICKDSF CONTROL CLEARFENCE can reset the soft fence on the device which allows the device to be brought online. ICKDSF CONTROL CLEARFENCE can reset soft fenced device and brings device online. KEYWORDS: D/T2107
Temporary fix
Comments
APAR Information
APAR number
OA67488
Reported component name
DEVICE SUPPORT
Reported component ID
5695DF111
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-02-05
Closed date
2025-04-24
Last modified date
2025-05-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ97056 UJ97057
Modules/Macros
IECDINIT
Fix information
Fixed component name
DEVICE SUPPORT
Fixed component ID
5695DF111
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"310"}]
Document Information
Modified date:
14 May 2025