A fix is available
APAR status
Closed as program error.
Error description
After apply of OA66714, zSecure Access monitor might issue a MSGC2P0571I which begins with the text "pid-nt already allocated ...". This might occur in cases where another started task is initializing and creating the same name token as zSecure Access monitor. The used storage cell is initialized after being freed, the free cell forward chain is cleared.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of zSecure Access Monitor started task * * (C2PACMON). * **************************************************************** * PROBLEM DESCRIPTION: zSecure Access monitor might issue a * * MSGC2P0571I followed by a MSGC2P0483W. * **************************************************************** * RECOMMENDATION: Apply the PTF provided. * **************************************************************** zSecure Access monitor started task (C2PACMON) might repeatedly issue a MSGC2P0571I which begins with the text "pid-nt already allocated ..." followed by a MSGC2P0483W which begins with the text "FRR routine invoked for ABEND 940C4000...". This might occur in cases where another started task is initializing and creating the same name token as zSecure Access monitor. The used storage cell is initialized after being freed, the free cell forward chain is cleared.
Problem conclusion
zSecure Access Monitor started task has been modified, so that it recovers from the condition reported by the MSGC2P0571I and continues to operate normally.
Temporary fix
Comments
APAR Information
APAR number
OA67475
Reported component name
ZSEC BASE,ADMIN
Reported component ID
5655T0100
Reported release
310
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-02-03
Closed date
2025-03-03
Last modified date
2025-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ96748
Modules/Macros
C2PUSCPC
Fix information
Fixed component name
ZSEC BASE,ADMIN
Fixed component ID
5655T0100
Applicable component levels
R310 PSY UJ96748
UP25/03/05 P F503 {
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSPQTM","label":"IBM Security zSecure Admin"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
02 April 2025