A fix is available
APAR status
Closed as program error.
Error description
MSGIEA304W against load module IEAVNP02 was followed by WAIT064-009 during IPL. The collected stand-alone dump showed that the WAIT state was the result of the S0C6 ABEND, triggered by not retaining important values before and after the FREEMAIN processing in load module IOSVNPTH. ANALYSIS: In the stand-alone dump, the very last entries in the system trace may look as follows (only significant data): 0001 03164780 SRB 00000000_000242E8 00000000 ... 00 IOSVNPTH 0001 03164780 SSRV 78 8103FD66 0300F502 ... Getmain IRDVDSE 0001 03164780 SSRV 78 8103FF1C 0000F503 ... Freemain -"- 0001 03164780 SSRV 78 8103FD66 0300F502 ... Getmain -"- 0001 03164780 SSRV 78 8103FF1C 0000F503 ... Freemain -"- 0001 03164780 SSRV 78 80022810 0000F503 ... Freemain IOSVNPTH 0001 03164780 SSRV 129 80024436 031D7F0C ... Post IOSVNPTH 0001 03164780 SSRV 78 80024928 0000F503 ... Freemain IOSVNPTH 0001 03164780 *PGM 006 00000000_0000F507 00040006 ... 00000000 Abend 0C6 Obviously, the value of X'0000F507' as the assumed address of the ABEND was the result of using the preceding value of X'0000F503' (Freemain with BRANCH=GLOBAL in Subpool 245 or X'F5') in the FREEMAIN entries as the address for the failed branch instruction. . ANALYSIS part II: The device number that was non-responsive to z/OS can be determined from the stand-alone dump. Obtain a stand-alone dump of the system. analyze the SYSTEM TRACE. search for a "Time-gap" message. shortly after the time gap message, Search for a XSCH record followed by a CSCH record. the device number undergoing the Cancel / Clear is the not responsive device. In this example device 0123 is the not responsive device. . ******** Time-gap over 0000000E secs. Previous timestamp= 02:13:42.33832691, Current timestamp= 02:13:56.92544333. 0001 00FD66F8 SVC 10 00000000_0001E252 00000018 00000028 0001FD6C Purge 02:13:56.925443330 07040000 80000000 0001 00FD66F8 . 0001 00FD66F8 . 0001 00FD66F8 . 0001 00FD66F8 XSCH 00123 <------ Device # 00123 0001 00000000 CSCH 00123 <------ Device # 00123 . VERIFICATION STEPS: See the Analysis section of the APAR.
Local fix
BYPASS/CIRCUMVENTION: None. In the case of a temporary device issue, a re-IPL might be successful, however a re-IPL is not likely to be productive. Obtain a stand-alone dump of the system for analysis. This APAR is HIPER. The appropriate PTF should be applied immediately RECOVERY ACTION: Apply the appropriate PTF Re-IPL the system
Problem summary
**************************************************************** * USERS AFFECTED: * * Users at HBB77C0 and above who have OA64741 * * installed. * **************************************************************** * PROBLEM DESCRIPTION: * * Customers with OA64714 installed may * * encounter message IEA304W indicating * * a WAITSTATE 064 with REASON CODE 009. * **************************************************************** * RECOMMENDATION: * **************************************************************** Customers with OA64714 installed may encounter a WAITSTATE 064 with REASON CODE 009. The WAITSTATE is the result of not saving the contents of a register prior to issuing a FREEMAIN and restoring the contents of the register after the FREEMAIN is issued.
Problem conclusion
The register in question is saved prior to issuing the FREEMAIN and then restored after the FREEMAIN has completed.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
OA67009
Reported component name
IOS
Reported component ID
5752SC1C3
Reported release
7E0
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-09-23
Closed date
2024-10-04
Last modified date
2025-06-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ96054 UJ96056 UJ96057
Modules/Macros
IOSVNPTH
Fix information
Fixed component name
IOS
Fixed component ID
5752SC1C3
Applicable component levels
R7D0 PSY UJ96057
UP24/10/16 P F410
R7E0 PSY UJ96054
UP24/10/16 P F410
R7C0 PSY UJ96056
UP24/10/16 P F410
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O","label":"IOS"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7E0"}]
Document Information
Modified date: