Error description

  • Although field QWHCEUTX has a length of 32 characters, when it
    is moved to table SMF101_SUMMARY_V2 the content of this field is
    truncated to 20 characters because END_USER_TRAN is defined as
    CHAR (without length).
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    OA66626

  • Reported component name

    ZLDA

  • Reported component ID

    5698ABH04

  • Reported release

    510

  • Status

    CLOSED DUB

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem