A fix is available
APAR status
Closed as program error.
Error description
The RACF command SETROPTS RVARYPW(SWITCH(xxxxxxxx) STATUS(yyyyyyyy) KDFAES) may abend when completing the HOLD ACTION for APAR OA65905: DUMP TITLE=jobname,ICHCOP00 MODULE,0C4-010 ABEND,UNKNOWN CSECT,UNKNOWN SEGMENT. ANALYSIS: The ABEND0C4 PIC10 occurs in ICHSGF00+2C UJ94764/UJ94776/UJ94775 after issuing a SETROPTS command with the RVARYPW and KDFAES keywords specified. KNOWN IMPACT: The command fails and the HOLD ACTION for APAR OA65905 cannot be completed. VERIFICATION STEPS: 1. Determine if APAR OA65905 is applied and the ABEND0C4 PIC10 was due to a SETROPTS command with the RVARYPW and KDFAES keywords specified. 2. From the dump, determine if the failing instruction is located in ICHSGF00+2C. ADDITIONAL SYMPTOMS: RACF, ABEND0C4 RSN10, ICHSGF00, SGFBUFFR
Local fix
BYPASS/CIRCUMVENTION: The failing SETROPTS command that caused the ABEND0C4 may work if issued again
Problem summary
**************************************************************** * USERS AFFECTED: RACF users issuing a SETROPTS RVARYPW * * command with the KDFAES keyword. * **************************************************************** * PROBLEM DESCRIPTION: The SETROPTS RVARYPW command can abend * * with an ABEND0C4 PIC10. * **************************************************************** The SETROPTS RVARYPW command can abend with an ABEND0C4 PIC10.
Problem conclusion
The SETROPTS RVARYPW command ABEND0C4 PIC10 is fixed.
Temporary fix
Comments
APAR Information
APAR number
OA66624
Reported component name
RACF
Reported component ID
5752XXH00
Reported release
7D0
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-06-10
Closed date
2024-09-03
Last modified date
2024-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ95895 UJ95896 UJ95897
Modules/Macros
IRRMXPW0
Fix information
Fixed component name
RACF
Fixed component ID
5752XXH00
Applicable component levels
R7C0 PSY UJ95895
UP24/10/02 P F410 {
R7D0 PSY UJ95896
UP24/10/02 P F410 {
R7E0 PSY UJ95897
UP24/10/02 P F410 {