A fix is available
APAR status
Closed as program error.
Error description
When using QSAM or BSAM to read a non-vsam physical sequential file that does not have an EOF marker, this may lead to tracks of data being read that do not fit the expected format of the dataset. This is because the data on these tracks is residual data.
Local fix
If the file being processed is an empty file, you should be able to open it for output and then close it. This will cause an EOF marker to be written.
Problem summary
**************************************************************** * USERS AFFECTED: All users of z/OS 2.5 and above * **************************************************************** * PROBLEM DESCRIPTION: A loop may occur if zHPF is used to * * read a non-VSAM sequential data set * * that contains one or more blocks with * * count fields that do not match * * the track address. * * ZHPF/K * ****************************************************************
Problem conclusion
Problem has been corrected.
Temporary fix
Comments
APAR Information
APAR number
OA66589
Reported component name
BASE ACCESS MET
Reported component ID
5695DF102
Reported release
250
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-06-03
Closed date
2024-10-30
Last modified date
2025-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ96246 UJ96247
Modules/Macros
IGG019FZ
Fix information
Fixed component name
BASE ACCESS MET
Fixed component ID
5695DF102
Applicable component levels
Fix is available