OA66589: LOOP WHEN READING A NON-VSAM SEQUENTIAL DATASET ON A ZHPF DEVICE THAT DOES NOT HAVE AN EOF

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using QSAM or BSAM to read a non-vsam physical sequential
    file that does not have an EOF marker, this may lead to tracks
    of data being read that do not fit the expected format of the
    dataset. This is because the data on these tracks is residual
    data.
    

Local fix

  • If the file being processed is an empty file, you should be able
    to open it for output and then close it. This will cause an EOF
    marker to be written.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of z/OS 2.5 and above              *
    ****************************************************************
    * PROBLEM DESCRIPTION: A loop may occur if zHPF is used to     *
    *                      read a non-VSAM sequential data set     *
    *                      that contains one or more blocks with   *
    *                      count fields that do not match          *
    *                      the track address.                      *
    *                      ZHPF/K                                  *
    ****************************************************************
    

Problem conclusion

  • Problem has been corrected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA66589

  • Reported component name

    BASE ACCESS MET

  • Reported component ID

    5695DF102

  • Reported release

    250

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-06-03

  • Closed date

    2024-10-30

  • Last modified date

    2025-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ96246 UJ96247

Modules/Macros

  • IGG019FZ
    

Fix information

  • Fixed component name

    BASE ACCESS MET

  • Fixed component ID

    5695DF102

Applicable component levels

  • R250 PSY UJ96247

       UP24/12/10 P F412

  • R310 PSY UJ96246

       UP24/12/10 P F412

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"250"}]

Document Information

Modified date:
02 January 2025