A fix is available
APAR status
Closed as new function.
Error description
New Function
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: RMF users * **************************************************************** * PROBLEM DESCRIPTION: Data Gatherer enhancements to * * support replacement capacity records * * for Tailored Fit Pricing for * * IBM Z hardware * **************************************************************** To support replacement capacity records for Tailor Fit Pricing for IBM Z hardware the z/OS Data Gatherer collects model replacement capacity identifier and ratings. This new information is stored in the CPU Control Section of SMF record type 70 subtype 1 and in the Home LPAR Section of Monitor III CPC data control block (ERBCPCDB). When APAR OA66402 is installed, SMF type 70.1 records with SMF record level x'92' are written. The version of measurement table ERBCPCDB (CPC_VerNum), located at offset x5 in the header section of CPCDB, is set to 14/x'0E'. In addition the description of multiple capacity identifiers is enhanced in SMF 70 subtype 1 to describe which portion of capacity is included or excluded. +-------------------------------------------------------------+ >>>>> SMF PRODUCT SECTION - SMF RECORD TYPE 70 SUBTYPE 1 <<<<< OFFSET NAME LEN FORMAT DESCRIPTION 51 x33 SMF70SRL 1 binary SMF record level change number. This field enables processing of SMF record level changes in an existing release. SMF type 70 record levels for the current z/OS release: Subtype Record level 1 X'92' (APAR OA66402) 2 X'8F' (APAR OA59330) +-------------------------------------------------------------+ >>>>> SMF RECORD TYPE 70 SUBTYPE 1 <<<<< >>>>> CPU Control Section <<<<< OFFSET NAME LEN FORMAT DESCRIPTION : 8 x8 SMF70MDL 16 EBCDIC CPC model identifier indicat- ing the total capacity of the CPC, including all types of active capacity. See bit 4 of SMF70STF. : 116 x74 SMF70MPC 16 EBCDIC CPC model identifier indicat- ing the permanent capacity of the CPC, without the temporar- ily increased capacity, the temporarily available replace- ment capacity and the corridor capacity. ... : 132 x84 SMF70MTC 16 EBCDIC CPC model identifier indicat- ting the temporary capacity of the CPC, which is the total of permanent capacity and tem- porarily increased capacity, without the temporarily avail- able replacement capacity and the corridor capacity. ... : 344 x158 SMF70MDL_VAR 16 EBCDIC CPC model identifier indicat- ing the variable capacity of the CPC. ... : 404 x194 * 4 * Reserved. 408 x198 SMF70MDL_REP 16 EBCDIC CPC model identifier indicat- ing the replacement capacity of the CPC, which is the total of permanent capacity, tem- porarily increased capacity, and temporarily available replacement capacity, without the corridor capacity. The identifier is left justi- fied with trailing blanks if necessary. This field is zero, if not supported by the hard- ware. 424 x1A8 SMF70MRCR 4 binary Model replacement capacity rating. When non-zero, this value is associated with the model capacity as identified in field SMF70MDL_REP. 428 x1AC SMF70NRCR 4 binary Nominal model-replacement- capacity-rating. When non-zero, this value is associated with the nominal model capacity as identified in field SMF70MDL_REP. When field SMF70CAI contains a value of 100, this value equals the value in field SMF70MRCR. +-------------------------------------------------------------+ >>>>> MONITOR III ERBCPCDB <<<<< CPC data control block - Home LPAR Section: OFFSET NAME LEN FORMAT DESCRIPTION : 800 x320 CPC_MRCI 16 EBCDIC EBCDIC model replacement capacity identifier. The identifier is left justi- fied with trailing blanks if necessary. This field is zero, if not supported by the hardware. 816 x330 CPC_MRCR 4 binary Model replacement capacity rating. When non-zero, this value is associated with the model capacity as identified in field CPC_MRCI. 820 x334 CPC_NomMRCR 4 binary Nominal model-replacement- capacity-rating. When non-zero, this value is associated with the nominal model capacity as identified in field CPC_MRCI. When field CPC_CapAdj contains a value of 100, this value equals the value in field CPC_MRCR.
Problem conclusion
Temporary fix
Comments
KEYWORDS: SMFREC/K E9175/K PRICINGINFR/K
APAR Information
APAR number
OA66402
Reported component name
RMF DATA GATHER
Reported component ID
566527401
Reported release
7C0
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2024-04-17
Closed date
2025-05-09
Last modified date
2025-05-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ96928 UJ96929 UJ96930
Modules/Macros
ERB3GCPC ERB3GGSS ERB3GINI ERB3GISS ERBMFDCP ERBMFICP ERBPPCON ERBSMF70 GRB3GCPC GRB3GGSS GRB3GINI GRB3GISS GRB3RACC GRB3RGTS GRBMFDCP GRBMFICP GRBPPCON GRBSMFRG
| SA380667XX | GC274935XX |
Fix information
Fixed component name
RMF DATA GATHER
Fixed component ID
566527401
Applicable component levels
R7C0 PSY UJ96928
UP25/05/28 I 1000
R7D0 PSY UJ96929
UP25/05/28 I 1000
R7E0 PSY UJ96930
UP25/05/28 I 1000
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7C0"}]
Document Information
Modified date:
28 May 2025