A fix is available
APAR status
Closed as program error.
Error description
Preparation APAR for new z/OS Data Gatherer USS installation path introduced with APAR OA66399.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: z/OS Data Gatherer users * **************************************************************** * PROBLEM DESCRIPTION: Provide new DDDEF and MKDIR jobs prior * * to installation of z/OS Data Gatherer * * APAR OA66399 * **************************************************************** * RECOMMENDATION: THIS SERVICE MUST BE APPLIED PRIOR TO APAR * * OA66399 AS REQUIRED SMP/E DDDEF AND USS * * DIRECTORY NEED TO BE CREATED. * **************************************************************** The installation of the PTF for APAR OA66399 requires that new SMP/E DDDEF SGRBUNIX as well as new USS directory /usr/lpp/grb are added to your installation. The installation of the PTF for APAR OA66399 will fail if the new DDDEF and new directory are not defined.
Problem conclusion
This PTF provides the sample jobs for defining the new DDDEF and for creating the new directory, which are the prerequisites for APAR OA66399.
Temporary fix
Comments
APAR Information
APAR number
OA66400
Reported component name
RMF DATA GATHER
Reported component ID
566527401
Reported release
7E0
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2024-04-17
Closed date
2024-06-21
Last modified date
2024-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ95531
Modules/Macros
GRB00DDF GRB01DDF GRBISMKD GRBMKDIR
Fix information
Fixed component name
RMF DATA GATHER
Fixed component ID
566527401
Applicable component levels
R7E0 PSY UJ95531
UP24/06/27 P F406
Fix is available