Error description

  • Then contents of some SMF230 subsections are not sent completely
    to distributed subscribers with HBO0153I reported.
    

Local fix

  • Following messages are received in SDE:
    HBO0153I The section ACLMFBSE of SMF_230_CA_16 is a section
    within ACFSMFLX which has no LENGTH
    
                                defined. The length of ? is defined
    by the length of its fields.
    
    
    When SDE starts up and all the fields contained in section
    ACLMFBSE, ACVMFDB2, ACFSMFML are not send to the  distributed
    subscribers.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All ZAA (IBM Z Anomaly Analytics with        *
    *                 Watson) and ZLDA (IBM Z Operational Log and  *
    *                 Data Analytics) V5.1 users of CDP (Common    *
    *                 Data Provider).                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Then contents of some SMF230            *
    *                      subsections are not sent completely to  *
    *                      distributed subscribers with HBO0153I   *
    *                      reported.                               *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF.                              *
    ****************************************************************
    There is no length specification in the main section which
    prevents SDE from obtaining the contents of related subsections.
    

Problem conclusion

  • CDP is updated to fix this defect.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA66224

  • Reported component name

    CDP BASE

  • Reported component ID

    5698ABJ00

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-03-06

  • Closed date

    2024-06-04

  • Last modified date

    2024-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ95350

Modules/Macros

  • HBOA2DUN HBOAIWLM HBOAKCUN HBOAKDUN HBOAKZUN HBOAPMUN HBOCCORN
    HBOCCORY HBOCCSV  HBOIMS   HBOJBCO2 HBOJBCOL HBOJBDC2 HBOJBDCO
    HBOJBIM2 HBOJBIMS HBOJBLG2 HBOJBLGR HBOJCOLL HBOLDCOL HBOLLREC
    HBOLLSMF HBOR1102 HBOR1103 HBOR110T HBOR1153 HBOR1154 HBOR1211
    HBOR1231 HBORDCOL HBORLREC HBORS000 HBORS002 HBORS003 HBORS004
    HBORS005 HBORS006 HBORS007 HBORS008 HBORS009 HBORS010 HBORS011
    HBORS014 HBORS015 HBORS016 HBORS017 HBORS018 HBORS019 HBORS020
    HBORS021 HBORS022 HBORS023 HBORS024 HBORS025 HBORS026 HBORS030
    HBORS032 HBORS033 HBORS034 HBORS035 HBORS036 HBORS037 HBORS038
    HBORS039 HBORS040 HBORS041 HBORS042 HBORS043 HBORS045 HBORS047
    HBORS048 HBORS049 HBORS050 HBORS052 HBORS053 HBORS054 HBORS055
    HBORS056 HBORS057 HBORS058 HBORS059 HBORS060 HBORS061 HBORS062
    HBORS064 HBORS065 HBORS066 HBORS070 HBORS071 HBORS072 HBORS073
    HBORS074 HBORS075 HBORS076 HBORS077 HBORS078 HBORS079 HBORS080
    HBORS081 HBORS082 HBORS083 HBORS084 HBORS085 HBORS088 HBORS089
    HBORS090 HBORS092 HBORS094 HBORS098 HBORS099 HBORS100 HBORS101
    HBORS102 HBORS103 HBORS104 HBORS110 HBORS111 HBORS113 HBORS114
    HBORS115 HBORS116 HBORS117 HBORS118 HBORS119 HBORS120 HBORS121
    HBORS123 HBORS124 HBORS125 HBORS129 HBORS132 HBORS194 HBORS230
    HBORS231 HBORSIMS HBORST80 HBORSX42 HBORSX72 HBORSX74 HBORSY42
    HBOSMF   HBOTA2AC HBOTA2AP HBOTAGGR HBOTALDA HBOTALKP HBOTALMI
    HBOTALSP HBOTALTR HBOTALUG HBOTALUT HBOTALW2 HBOTALWL HBOTCIFI
    HBOTD2AP HBOTD2PL HBOTDSPE HBOTDWEK HBOTKZTH HBOTMVWL HBOTPERI
    HBOTRAEV HBOTRAOA HBOU1102 HBOU1103 HBOU110I HBOU1153 HBOU1154
    HBOU1211 HBOU1231 HBOUA2D1 HBOUA2D2 HBOUA2D3 HBOUA2D4 HBOUA2D5
    HBOUA2D6 HBOUA2D7 HBOUA2D8 HBOUAKC1 HBOUAKD1 HBOUAKD2 HBOUAKD3
    HBOUAKZ1 HBOUAKZ2 HBOUAKZ3 HBOUAKZ4 HBOUAKZ6 HBOUAKZ7 HBOUAKZ8
    HBOUAKZ9 HBOUAPM1 HBOUAPM2 HBOUAPM3 HBOUAPM4 HBOUAPM5 HBOUAPM7
    HBOUAPM8 HBOUAPM9 HBOUAPMA HBOUAPMB HBOUAPMC HBOUCMFR HBOUCMFT
    HBOUCMFU HBOUD2AA HBOUD2BP HBOUD2DU HBOUD2PU HBOUD2T  HBOUD2UT
    HBOUDCOL HBOUITLS HBOUKCMT HBOUKD01 HBOUKD02 HBOUKD03 HBOUKD04
    HBOUKD05 HBOUKD06 HBOUKD07 HBOUKD08 HBOUKD09 HBOUKD10 HBOUKZCF
    HBOUKZCH HBOUKZCS HBOUKZH1 HBOUKZH2 HBOUKZJI HBOUKZJS HBOUKZLP
    HBOUKZSR HBOUKZST HBOUKZWK HBOULREC HBOUR110 HBOURIMS HBOURSMF
    HBOUS000 HBOUS002 HBOUS003 HBOUS004 HBOUS005 HBOUS006 HBOUS007
    

Fix information

  • Fixed component name

    CDP BASE

  • Fixed component ID

    5698ABJ00

Applicable component levels

  • R510 PSY UJ95350

       UP24/06/18 P F406

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"510"}]

Document Information

Modified date:
01 July 2024