A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4-11 in IGC121 when using HPU ANALYSIS: VSAM was attempting to pull the JSTCB from the ASCB (address space control block) and update the JSTCB field in the IOMB. VSAM pulls a TCB from the TCB dispatcher queue. At the time of error VSAM was running under an SRB which had been suspended. While the SRB was suspended the TCB VSAM had picked up from the ASCB had terminated and storage was cleared. When the SRB was resumed, VSAM attempted to touch this area of storage which had been freed resulting in the ABEND0C4. KNOWN IMPACT: ABEND0C4-11 in IGC121 +x'454' (z/OS 2.5 base) VERIFICATION STEPS: A dump is generated with the following title "Dump Title: COMP=VSAM-ABP,COMPID=5695DF106,ISSUER=IDA121F1" Reg12 points to a TCB address where storage is not available. CATKEYS: VSAM2023 VSAMABEND VSAMHPU
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All VSAM users running in SRB or XMM mode. * **************************************************************** * PROBLEM DESCRIPTION: * * ABEND0C4-11 in IGC121 when running * * in SRB or XMM mode. * **************************************************************** * RECOMMENDATION: * * Apply PTF. * **************************************************************** VSAM I/O routine is picking up the jobstep TCB address from the last TCB in the dispatching queue while running under a SRB or in XMM mode. A rare timing problem is possible when the last TCB in the dispatching queue is detached at the same time VSAM is trying to use the address to reference the jobstep TCB. If this happens, an ABEND0C4 may occur.
Problem conclusion
VSAM I/O routine is now corrected to use the jobstep TCB that was saved during OPEN time while running under a SRB or in XMM mode.
Temporary fix
Comments
APAR Information
APAR number
OA65906
Reported component name
DFSMS VSAM
Reported component ID
5695DF106
Reported release
250
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-12-11
Closed date
2024-03-05
Last modified date
2024-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ94769 UJ94770 UJ94771
Modules/Macros
IGC121
Fix information
Fixed component name
DFSMS VSAM
Fixed component ID
5695DF106
Applicable component levels
R310 PSY UJ94769
UP24/03/27 P F403
R250 PSY UJ94771
UP24/03/27 P F403
R240 PSY UJ94770
UP24/03/27 P F403
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"250"}]
Document Information
Modified date:
04 April 2024