A fix is available
APAR status
Closed as new function.
Error description
Extending the support for hardware-only dynamic changes in z/OS HCD to IBM z16 and IBM LinuxONE 4 processors in standard (non-DPM) mode which host Linux on Z (including SSC - Secure Service Containers) images. and/or z/Transaction Processing Facility (z/TPF) instances . Hardware-only changes allow to change the hardware I/O configuration of an IBM z16 or IBM LinuxONE 4 dynamically while the processor remains running. It is needed if there is no instance of z/OS HCD or z/VM HCD running on that processor to process these changes. This capability is intended to avoid the need for disruptive actions to be taken to instantiate hardware I/O configuration changes. It extends the benefits of the existing dynamic I/O activation capability beyond just standalone Coupling Facilities as target processor. It eliminates the customer workload impact that would have otherwise been caused by taking down those Linux on Z and/or z/TPF images. This new function is only supported if the z/OS system running HCD is also running on an IBM z16. Note: Any z/16 and LinuxONE 4 processor involved in this process needs the required firmware support level: Z16 Driver 51 - CPC Bundle S27 (or higher). The specific EC that deliver this support are: Driver 51 SE-HAWK EC P30785 MCL003 (or higher) Driver 51 SE-SYSTEM EC P30713 MCL018 (or higher)
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All HCD users with the need to make * * hardware-only dynamic changes as described * * in the Error Description. * **************************************************************** * PROBLEM DESCRIPTION: Extending the support for hardware-only * * dynamic changes in z/OS HCD to IBM z16 * * and IBM LinuxONE 4 processors in * * standard (non-DPM) mode which host * * Linux on Z and/or IBM z/Transaction * * Processing Facility (z/TPF) instances. * * * * Hardware-only changes allow to change * * the hardware I/O configuration of an * * IBM z16 or IBM LinuxONE 4 dynamically * * while the processor remains running. * * It is needed if there is no instance * * of z/OS HCD or z/VM HCD running on that * * processor to process these changes. * * * * This capability is intended to avoid * * the need for disruptive actions to be * * taken to instantiate hardware I/O * * configuration changes. It extends the * * benefits of the existing dynamic I/O * * activation capability beyond just * * standalone Coupling Facilities * * as target processor. And it eliminates * * the customer workload that would have * * otherwise been caused by taking down * * those Linux on Z and/or z/TPF images. * * * * This new function is only supported if * * the z/OS system running HCD is also * * running on an IBM z16. * * * * Note: Any z16 and LinuxONE 4 processor * * involved in this process needs the * * required firmware support (S25 or * * higher). * **************************************************************** * RECOMMENDATION: none. * **************************************************************** With this APAR, HCD supports dynamic hardware-only changes targeting z16 hosting IBM Linux on Z and/or z/TPF images. The panels and helps are updated accordingly. Before this APAR, the target processor had to be a standalone Coupling Facility ("SACF") processor.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
OA65559
Reported component name
MVS/HCD
Reported component ID
5695SC1XL
Reported release
7E0
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2023-09-18
Closed date
2023-10-25
Last modified date
2024-01-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ93969 UJ93970 UJ93971
Modules/Macros
CBDDPA1 CBDF161 CBDF4TP CBDHPF0 CBDHPFA CBDHY50 CBDMHHIT CBDPACFA CBDPDY50 CBDPDY55
Fix information
Fixed component name
MVS/HCD
Fixed component ID
5695SC1XL
Applicable component levels
R7C0 PSY UJ93971
UP23/10/26 P F310
R7D0 PSY UJ93970
UP23/10/26 P F310
R7E0 PSY UJ93969
UP23/10/26 P F310
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19O"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"7E0"}]
Document Information
Modified date:
11 January 2024