Error description
When issuing multiple LISTC LVL() OUTFILE() ALL commands in batch, ABEND0C4 IN IDCTP01 UJ08761 at x+20C8 Note: In z/OS V2R5 DFSMS with APAR OA65387 applied and subsequent releases, the "LISTING FROM CATALOG -- catalog-name" message has been restored to each page header to the OUTFILE when running IDCAMS LISTCAT LVL command as it was pre-z/OS V2R5 CATKEYS: IDC2023 IDCABEND IDCLISTC ANALYSIS: IDCAMS trys to execute a MVC to the storage where REG3 points, to create the SUBTITLE Line for the LISTC output. KNOWN IMPACT: The BATCH JOB fails with ABEND0C4-4. VERIFICATION STEPS: Confirm that multiple LISTCAT LVL() OUTFILE() commands were issued in batch, and that the enviroment has IAM software active. Then via IPCS, verify that REG3 points to Key0 Storage, and that the PSW is in Key8. PE INFORMATION: USERS AFFECTED: APAR OA63298 (UJ08880) introduced a defect causing ABEND0C4 IN IDCTP01 UJ08761 at x+20C8, when issuing LISTC LVL() OUTFILE() USER IMPACT: APAR OA63298 fixed the problem it reported but introduced a new problem.
Local fix
BYPASS/CIRCUMVENTION: Remove UJ08880, steplib to a version of IDCAMS without UJ08880,
Problem summary
**************************************************************** * USERS AFFECTED: All users of IDCAMS LISTCAT LEVEL release * * z/os level2,5 and higher issuing the * * LITCAT via the Problem Program Interface * **************************************************************** * PROBLEM DESCRIPTION: LISTC LVL() OUTFILE() ALL ENDS WITH * * ABEND0C4 IN IDCTP01 * **************************************************************** The 0C4 was caused by changes that called a needed procedure that got control blocks. The code is changed to add back in the calls to those procedures.
Problem conclusion
The problem is fixed. Apply the maintenance and rerun.
Temporary fix
Comments
APAR Information
APAR number
OA65387
Reported component name
ACCESS METHOD S
Reported component ID
5695DF103
Reported release
250
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-08-16
Closed date
2024-10-21
Last modified date
2026-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ96175 UJ96179
Modules/Macros
IDCLC05 IDCLC09
Fix information
Fixed component name
ACCESS METHOD S
Fixed component ID
5695DF103
Applicable component levels
Fix is available