Error description

  • If the IFAQUERY service is called after SMF has terminated
    via an ABEND of some kind, the program issuing the IFAQUERY
    will fail with ABEND 06D RSN=27.  Instead, since SMF is not
    active, IFAQUERY should return with RC=12.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Installations running HBB77C0 or above.                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * An ABEND0D6 RSN27 may occur if the                           *
    * IFAQUERY macro service is invoked                            *
    * when SMF is not active                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    A program that invokes the IFAQUERY executable macro when SMF
    is not active may fail with ABEND0D6 RSN27.  This is because
    the IFAQUERY PC number is not valid if SMF is not active on the
    system.
    

Problem conclusion

  • The IFAQUERY executable macro is updated to issue a return code
    of 12 ('0C'x) with a reason code of '0C01'x if SMF is not
    active.
    
    Note: Programs that call IFAQUERY must be recompiled to include
    the updated IFAQUERY code provided by this APAR.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA65166

  • Reported component name

    SMF SCHEDULER

  • Reported component ID

    5752SC100

  • Reported release

    7C0

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-07-07

  • Closed date

    2023-08-31

  • Last modified date

    2023-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UJ93618 UJ93625 UJ93626

Modules/Macros

  • IFAQUERY
    

Fix information

  • Fixed component name

    SMF SCHEDULER

  • Fixed component ID

    5752SC100

Applicable component levels

  • R7D0 PSY UJ93626

       UP23/09/20 P F309

  • R7E0 PSY UJ93618

       UP23/09/20 P F309

  • R7C0 PSY UJ93625

       UP23/09/20 P F309

Fix is available