A fix is available
APAR status
Closed as program error.
Error description
Catalog suffers an ABEND S0C9 when doing performance calculations after catalog address space has been running for a long period of time. ANALYSIS: The PSW for the abending TCB, will point to offset +x'1C50' into IGG0CLF0, and Register 12 will be all ZEROS, because the count has wrapped, and CATALOG is attempting to execute DSGR (Divide by single grande) with a zero in the divisor KNOWN IMPACT: Catalog takes a dump, and continue processing, but the catalog performance statistics will be incorrect until catalog is restarted. VERIFICATION STEPS: Using IPCS, verify register 12 at time of error is all zeros. ADDITIONAL KEYWORDS: CATKEYS: CAT2023 CATABEND
Local fix
BYPASS/CIRCUMVENTION: Restart Catalog Address Space periodically RECOVERY ACTION: Restart Catalog Address space to reset performance information
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of HDZ2240 and up * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description. * **************************************************************** * RECOMMENDATION: * **************************************************************** The code causing the 0C9 has been removed.
Problem conclusion
The calculation of some statistics was flawed. The flawed calculations are currently not used so were removed (for now).
Temporary fix
Comments
APAR Information
APAR number
OA64730
Reported component name
ICF CATALOG & I
Reported component ID
5695DF105
Reported release
240
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-04-20
Closed date
2023-09-25
Last modified date
2024-01-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ93786 UJ93789 UJ93790
Modules/Macros
IGG0CLF0
Fix information
Fixed component name
ICF CATALOG & I
Fixed component ID
5695DF105
Applicable component levels
R310 PSY UJ93786
UP23/10/17 P F310
R250 PSY UJ93790
UP23/10/17 P F310
R240 PSY UJ93789
UP23/10/17 P F310
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"240"}]