A fix is available
APAR status
Closed as program error.
Error description
A SYSDSN ENQ is held whenever a browse session is started. The ENQ protects data from going away while the browse session (IXGBRWSE) is active. It also prevents a particular log stream data set from being deleted if the browse cursor is currently positioned on that particular data set. For long running browse sessions that simply read data from oldest to youngest, it may cause the SYSDSN ENQ to be held even though the browse cursor is nowhere near the data set with the ENQ.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of HBB77C0 and above releases * * using System Logger Services. * **************************************************************** * PROBLEM DESCRIPTION: * * Long running browse (IXGBRWSE) * * session results in IXG284I message * * due to SYSDSN ENQ held against a * * log stream data set. * **************************************************************** * RECOMMENDATION: * **************************************************************** When a browse session is started and its read cursor falls on data that resides in a log stream data set, a SYSDSN ENQ is held to ensure the data set does not get deleted. For long running browse sessions that simply read data from oldest to youngest, this may result in the SYSDSN ENQ being held even when the read cursor no longer points to the associated data set. This happens when the read cursor points beyond the log stream data set and points to data that is in interim storage.
Problem conclusion
System Logger is changed to release the SYSDSN ENQ when the read cursor transitions from data on DASD to data in interim storage. Additional Searchable keywords: SYSPLEXDS
Temporary fix
Comments
×**** PE24/04/11 FIX IN ERROR. SEE APAR OA66388 FOR DESCRIPTION ×**** PE24/04/11 FIX IN ERROR. SEE APAR OA66388 FOR DESCRIPTION
APAR Information
APAR number
OA64560
Reported component name
SYSTEM LOGGER
Reported component ID
5752SCLOG
Reported release
7C0
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-03-20
Closed date
2023-12-11
Last modified date
2024-07-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UJ94285 UJ94286 UJ94287
Modules/Macros
IXGA1RED IXGF2BRW
Fix information
Fixed component name
SYSTEM LOGGER
Fixed component ID
5752SCLOG
Applicable component levels
R7D0 PSY UJ94287
UP23/12/27 P F312 ¢
R7E0 PSY UJ94285
UP23/12/27 P F312 ¢
R7C0 PSY UJ94286
UP23/12/27 P F312 ¢
Fix is available